In this mode, the RDS monitors one or two RF signals independently. Alarms will trigger when
the RF signal level of one (or both) inputs fall below the preset threshold for that port (1 or 2).
This mode of operation is virtually the same as the A/B switch mode, except that the RDS is
programmed not to switch from the A to B side when a failure is detected—the failure is simply
logged and identified. The output power levels of the receivers or amplifiers being monitored
must fall within the input power ranges for the RDS specified in
2.2
Physical Description
show physical dimensions of the RDS.
Figure 5. Top View With Dimensions
Figure 6. Front View With Dimensions
17.20 IN.
(43.69 CM)
7.44 IN.
(18.9 CM)
12.0 IN.
(30.5 CM)
CABLE
MANAGEMENT
BAR
12215-C
2A 240V
V: 38.4–57.6 VDC/100/120/240 VAC
Ø: 1
A: 1A MAX DC / 2A MAX AC
HZ: 47–63 HZ
U R
1.25 IN.
(3.18 CM)
1.75 IN.
(4.45 CM)
18.31 IN.
(46.51 CM)
18.98 IN.
(48.21 CM)
10152-C
PATENT PENDING