Power
SCP-PCS718-010-06H
24
January 6, 2003
PCS-718 List 1
Powering the Integrated Systems
summarizes the shelf powering requirements and heat dissipation for the PG-Flex<italics 10>PG Plus
COT shelf when it is fully populated with services, a battery voltage of –48.0 V, and with all CO to RT distances
at their maximum DSL reach. The table provides the average current drawn from a fully populated shelf under the
these conditions.
.
The conditions in
assume that the POTS lines at all customer sites are off hook.
The configuration used for computing the shelf current and heat dissipation includes two PMXs and one
PAU or PMU.
Table 18.
PCS-718 Shelf Power and Heat Dissipation for Integrated Systems
Service
Models
Split Powering
Single or Redundant
Powering
CO Heat
Dissipation
CO Input
Current
*
(*) Indicates the current when all lines are off hook with all DSL lines at maximum length with –48 Vdc battery.
Shelf
Fuse
†
(†) Indicates the recommended fuse for –42.5 Vdc battery and 15% fuse margin.
CO Input
Current
(a)
Shelf
Fuse
(b)
4 POTS
PLL-725
PRL-770
1.94 A
3.00 A
3.62 A
5.00 A
61 W
6 POTS
PLL-725
PRL-771
2.36 A
3.00 A
4.46 A
7.50 A
67 W
3 POTS, 1 ISDN
PLL-725
PRL-772
1.88 A
3.00 A
3.00 A
5.00 A
62 W
2 ISDN
PLL-725
PRL-773
1.58 A
2.00 A
2.90 A
5.00 A
61 W
6 UVG
PLL-725
PRL-779
2.77 A
5.00 A
5.28 A
7.50 A
79 W
4 POTS
(dual)
PLL-735
PRL-770
3.49 A
5.00 A
6.64 A
10.00 A
94 W
6 POTS
(dual)
PLL-735
PRL-771
4.33 A
7.50 A
8.32 A
12.00 A
105 W
3 POTS, 1 ISDN
(dual)
PLL-735
PRL-772
3.37 A
5.00 A
6.41 A
10.00 A
96 W
2 ISDN
(dual)
PLL-735
PRL-773
2.76 A
5.00 A
5.17 A
7.50 A
93 W
6 UVG
(dual)
PLL-735
PRL-779
5.18 A
7.50 A
10.01 A
15.00 A
133 W
24 POTS
‡
(No Doublers)
(‡) Indicates the subscriber drop set for LONG is
≤
960
Ω
.
FLL-814
FRL-842
4.90 A
7.50 A
9.46 A
15.00 A
106 W
24 POTS
(c)
(1 Doubler)
FLL-814
FRL-842
5.34 A
7.50 A
10.34 A
15.00 A
112 W
24 POTS
(c
(2 Doublers)
FLL-814
FRL-842
5.99 A
7.50 A
11.64 A
20.00 A
123 W
24 POTS
**
(No Doublers)
(**) Indicates the subscriber drop set for SHORT is
≤
830
Ω
.
FLL-814
FRL-842
3.56 A
5.00 A
6.75 A
10.00 A
84 W
24 POTS
(d)
(1 Doubler)
FLL-814
FRL-842
4.00 A
7.50 A
7.63 A
12.00 A
102 W
24 POTS
(d)
(2 Doublers)
FLL-814
FRL-842
4.38 A
7.50 A
8.38 A
12.00 A
102 W