Powering the System
summarizes the powering requirements and heat dissipation for the PSC-822 when it is fully populated with
a battery voltage of –48.0 V, and with all CO to RT distances at their maximum DSL reach. The table provides the
average current drawn for a fully populated Field Shelf under these conditions.
Table 9. PCS-822 Field Shelf Power Consumption and Heat Dissipation
The conditions in
assume that the POTS lines at all customer sites are off hook.
Each configuration assumes the use of one Management Unit and 2 MUXs (
Service
Models
Input Current
a
a. Indicates the current when all lines are off hook with all DSL lines at maximum length with -48 Vdc battery
Fuse
b
b. Indicates the recommended fuse for -42.5 Vdc battery and 15% fuse margin
Heat Dissipation
4 POTS
(dual)
PLL-735
PRL-770
4.9 A
7.5 A
82.6 W
6 POTS
(dual)
PLL-735
PRL-771
6.0 A
10.0 A
90.1 W
3 POTS, 1 ISDN
(dual)
PLL-735
PRL-772
4.7 A
7.5 A
84.0 W
2 ISDN
(dual)
PLL-735
PRL-773
3.8 A
7.5 A
81.6 W
6 UVG
(dual)
PLL-735
PRL-779
5.1 A
7.5 A
99.0 W
24 POTS
c
(No Doublers)
c. Indicates the subscriber drop set for LONG is
≤
960
Ω
FLL-814
FRL-842
5.7 A
10.0 A
82.2 W
24 POTS
c
(1 Doubler)
FLL-814
FRL-842
7.1 A
10.0 A
92.0 W
24 POTS
c
(2 Doublers)
FLL-814
FRL-842
8.4 A
12.0 A
101.2 W
24 POTS
d
(No Doublers)
d. Indicates the subscriber drop set for SHORT is
≤
830
Ω
Please refer to the appropriate AMX/PMX and AMU/PMU Technical Practice for system configuration
options.
FLL-814
FRL-842
4.9 A
7.5 A
76.7 W
24 POTS
d
(1 Doubler)
FLL-814
FRL-842
5.7 A
10.0 A
82.8 W
24 POTS
d
(2 Doublers)
FLL-814
FRL-842
6.6 A
10.0 A
88.6 W
3 POTS/1 ADSL
ALU-935
ARB-963
5.6 A
7.5 A
99.4 W
6 POTS/1 ADSL
ALU-935
ARB-964
6.1 A
10.0 A
93.0 W
8 ADSL (Dual)
ALU-935
ARL-942
7.1 A
10.0 A
101.3 W