ADC PCS-822 Technical Practice Download Page 16

SCP-PCS822-021-03H

January 6, 2003

6

ADC Telecommunications, Inc.

Figure 6

 shows the configuration for PG-Flex

Plus 

FPR-806 Remote POTS (RPOTS) applications. This is a basic 

universal channel bank architecture. Two DS1s are required for service and an optional third pair may be used for 
circuit protection. This configuration cannot be combined with other configurations described in this section.

Figure 6. PCS-822 Application – RPOTS

NIU #1

NIU #2

NIU #3

Sl

ot

#1

Sl

o

t

#

2

Slo

t

#

3

Sl

o

t

#4

Slot

#

5

Sl

o

t

#6

Sl

o

t

#7

Sl

o

t

#8

Management

and

Multiplex

Units

FPR-806

FPR-806

FPR-806

FPR-806

FPR-806

FPR-806

FPR-806

FPR-806

2 DS1s - Service

1 DS1 - Protection

(optional)

6 POTS Drops

per FPR-806

PCS-822

Field Shelf

Analog

CPE

Summary of Contents for PCS-822

Page 1: ...Section SCP PCS822 021 03H PG FlexPlus Field Shelf Technical Practice Model List CLEI Code PCS 822 2A S9MSGMGB...

Page 2: ......

Page 3: ...Inc and shall not be modified used copied reproduced or disclosed in whole or in part without the written consent of ADC Contents herein are current as of the date of publication ADC reserves the rig...

Page 4: ...item If the shipment is short or irregular contact ADC as described in Product Support on page 33 If you must store the equipment for a pro longed period store the equipment in its original container...

Page 5: ...ols and Test Equipment 13 Hardware Included with the Kit 13 Installing the Brackets 14 Preparing the Field Shelf 15 Attaching the Field Shelf 16 PCS 822 Ground Connections 17 Cable Locations 19 PFU 83...

Page 6: ...SCP PCS822 021 03H January 6 2003 iv ADC Telecommunications Inc...

Page 7: ...AM 8 Figure 9 PCS 822 Application Edge IAD and Edge RAM 9 Figure 10 PCS 822 Application 4 6 24 Channel Systems Edge IAD and RAM Systems 10 Figure 11 Alarm Circuits 11 Figure 12 Mounting the Brackets 1...

Page 8: ...SCP PCS822 021 03H January 6 2003 vi ADC Telecommunications Inc...

Page 9: ...cifications 12 Table 3 Cable Wire Gauge and Length 13 Table 4 Network Screened Cable Circuit Assignments 23 Table 5 DSL Cable Circuit Assignments 24 Table 6 Subscriber Cable Circuit Assignments 25 Tab...

Page 10: ...SCP PCS822 021 03H January 6 2003 viii ADC Telecommunications Inc...

Page 11: ...S0s of Time Division Multiplex TDM services and up to 128 PVCs for ATM services These slots support external interfaces of T1 High bit rate Digital Subscriber Loop HDSL or HDSL2 PCT 850 cards can also...

Page 12: ...2 Block Diagram CAUTION If you use a PCT 850 card with any input signal other than a DSX 1 the MUX card may be damaged This type of damage is not covered by the ADC warranty The NIU and MUX must be co...

Page 13: ...services and are powered from the PLL 735s installed in the Field Shelf The four DS1 circuits provide 96 DS0s of service with the optional fifth DS1 providing a protection circuit Figure 3 PCS 822 App...

Page 14: ...e locally powered to eliminate the need for the power pairs The four DS1 circuits provide 96 DS0s of service with the optional fifth DS1 providing a protection circuit Figure 4 PCS 822 Application 24...

Page 15: ...and DS1 circuits apply for this configuration as with the FLL 814 configurations previously described Figure 5 PCS 822 Application 4 6 24 Channel Systems NIU 1 NIU 2 NIU 3 NIU 4 NIU 5 Slot 4 Slot 5 Sl...

Page 16: ...ptional third pair may be used for circuit protection This configuration cannot be combined with other configurations described in this section Figure 6 PCS 822 Application RPOTS NIU 1 NIU 2 NIU 3 Slo...

Page 17: ...ises to separate the ADSL and POTS signals Four DS1 s provide up to 96 DS0 s of TDM voice and 4 DS1 s provide up to 16 PVC s of ATM data Figure 7 PCS 822 Application Edge IAD NIU 1 NIU 2 NIU 3 NIU 4 N...

Page 18: ...er source of dial tone Four DS1 circuits provide up to 24 PVC s of ATM data for each RAM Figure 8 PCS 822 Application Edge RAM NIU 5 NIU 6 NIU 7 NIU 8 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7...

Page 19: ...re 9 PCS 822 Application Edge IAD and Edge RAM NIU 1 NIU 2 NIU 3 NIU 4 NIU 5 NIU 6 NIU 7 NIU 8 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Management and Multiplex Units 4 DS1s TDM 4 DS1s...

Page 20: ...hannel Systems Edge IAD and RAM Systems NIU 1 NIU 2 NIU 3 NIU 4 NIU 5 NIU 6 NIU 7 NIU 8 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Management and Multiplex Units 4 DS1s TDM 4 DS1s ATM POT...

Page 21: ...ppropriate Management Unit documentation for information on provisioning these alarms Figure 11 Alarm Circuits The Field Shelf Fan Unit and Management Unit must be installed in the Field Shelf to supp...

Page 22: ...Compliance NEBS SR 3580 Level 3 GR 63 CORE Equipment is compliant with the applicable environmental sections when installed in a pedestal GR 487 CORE Equipment is compliant with the applicable environ...

Page 23: ...an Head Phillips Screws Four 10 Flat Washers Four 3 8 Spacers Four 10 32 x 3 8 Pan Head Phillips Screws or Two Mounting Brackets Four 1 4 20x Captive Hex Head Screws Four 1 4 Cup Washers Four 1 2 Spac...

Page 24: ...ground clamp attached to the divider panel is required for grounding the Field Shelf and pedestal PCS 822 Ground Connections on page 17 2 Install the mounting brackets using the hardware from step 1...

Page 25: ...1 4 20x Captive Hex Head Screw followed by one 1 2 spacer 2 Repeat step 1 three times to build a total of four spacer assemblies 3 On each side of the Field Shelf install two spacer assemblies Figure...

Page 26: ...g the Field Shelf 3 Use the 10 32 x 3 8 Pan Head Phillips screws or 1 4 20 x 1 2 Hex Washer Head screws to secure the Field Shelf to the mounting brackets Figure 15 Figure 15 Securing the Field Shelf...

Page 27: ...round bar and terminate the ground wires 1 Locate the ground clamp assembly on the divider panel previously removed from the pedestal Figure 16 Figure 16 NCAD 16 C Divider Panel and Ground Clamp Assem...

Page 28: ...pedestals Figure 18 5 Mount the ground bar to the pedestal rail holes prepared in step 4 using 20 x hardware included with the pedestal Figure 18 Mounting the Ground Bar to the Pedestal 6 Cut the gre...

Page 29: ...ution when bending the cable to avoid kinking the cable and damaging the shielding and or insulation CAUTION FAN MOVING FAN BLADES DOOR SWITCH TEST MADE IN U S A PFU 830 FAN FAIL LIST 1 5 1 6 10 20 15...

Page 30: ...se low rpm alarm If the fan fail LED remains off after holding the fan test button down for four seconds or more then the fan unit has passed the fan test If there is a fan failure the fan fail LED is...

Page 31: ...03 SCP PCS822 021 03H ADC Telecommunications Inc 21 PCT 850 CARDS Use the PCT 850 with DSX 1 operation or replace the PCT 850 with the appropriate T1 HDSL or HDSL2 interface cards Figure 21 Figure 21...

Page 32: ...e This screen isolates the network receive lines from the network transmit lines to avoid crosstalk problems Table 4 on page 23 CAUTION If you use a PCT 850 card with any input signal other than a DSX...

Page 33: ...SL Loop 2 5 5 WH SL 5 Tx Side 2 HDSL Loop 2 6 6 RD BL 6 Tx Side 2 HDSL Loop 2 7 7 RD OR 7 Tx Side 2 HDSL Loop 2 8 8 RD GN 8 Tx Side 2 HDSL Loop 2 9 RD BN 10 RD SL 11 BK BL 12 BK OR SP 1 RD WH SP 2 BK...

Page 34: ...35 WH BL 1 1 A DSL 1 PWR 1 2 36 WH OR 1 B DSL 1 PWR 2 3 37 WH GN 2 2 A DSL 1 DSL 1 4 38 WH BN 2 B DSL 1 DSL 2 5 39 WH SL 3 3 A DSL 2 PWR 1 6 40 RD BL 3 B DSL 2 PWR 2 7 41 RD OR 4 4 A DSL 2 DSL 1 8 42...

Page 35: ...Telephone No Cable Pair Protector Socket Cable Stub Slot Circuit Binder Tip Ring 1 51 BLUE WH BL 1 1 2 52 WH OR 2 3 53 WH GN 3 4 54 WH BN 4 5 55 WH SL 5 6 56 RD BL 6 7 57 RD OR 2 7 8 58 RD GN 8 9 59 R...

Page 36: ...RD GN 8 34 83 RD BN 9 35 84 RD SL 10 36 85 BK BL 11 37 86 BK OR 12 38 87 BK GN 7 13 39 88 BK BN 14 40 89 BK SL 15 41 90 YL BL 16 42 91 YL OR 17 43 92 YL GN 18 44 93 YL BN 8 19 45 94 YL SL 20 46 95 VI...

Page 37: ...e input and output alarms are routed out of the PCS 822 on the alarm cable Each alarm is connected to a pair of wires Table 7 Table 7 Alarm Cable Circuit Assignments ALARM CABLE CIRCUIT ASSIGNMENTS Ci...

Page 38: ...ugh the right hand protection block Subscriber drops are routed through the left hand block FPR 806 applications only Figure 22 Figure 22 Protection Block 46 41 36 31 6 26 21 11 16 1 50 45 40 35 10 30...

Page 39: ...ttery supply Note on page 1 Table 8 Power Cable Figure 23 PCS 822 3 Pair Power Cable DANGER Failure to properly fuse the PCS 822 can result in personal harm damage to equipment or loss of service DANG...

Page 40: ...for 42 5 Vdc battery and 15 fuse margin Heat Dissipation 4 POTS dual PLL 735 PRL 770 4 9 A 7 5 A 82 6 W 6 POTS dual PLL 735 PRL 771 6 0 A 10 0 A 90 1 W 3 POTS 1 ISDN dual PLL 735 PRL 772 4 7 A 7 5 A 8...

Page 41: ...DS0 Digital Signal Level 0 DS1 Digital Signal Level 1 DSL Digital Subscriber Line DSLAM Digital Subscriber Line Access Multiplexer DSX 1 Digital Subscriber Cross Connect Level 1 E ESD Electrostatic D...

Page 42: ...003 32 ADC Telecommunications Inc R RAM Remote Access Module RMA Return Material Authorization RT RemoteTerminal S SHDSL Synchronous High Speed Digital Subscriber Loop T TDM Time Division Multiplexer...

Page 43: ...ted below Telephone 800 366 3891 Email Address rma ADC com 3 Include the following information in writing along with the equipment you are returning Company name and address Contact name and telephone...

Page 44: ...rantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment...

Page 45: ......

Page 46: ...World Headquarters ADC Telecommunications Inc 12501 Whitewater Drive Minnetonka Minnesota USA 55343 For Technical Assistance 800 366 3891 8D 1215308...

Reviews: