ADC Telecommunications, Inc.
1
O
VERVIEW
The PG-Flex
Plus
TM
PCS-822 List 2A Field Shelf (
) supports POTS, ADSL and ISDN services. ADSL is pro-
vided through Edge Internet Access Devices (IADs) and Remote Access Modules (RAMs). Any combination of up
to eight PG-Flex
Plus
PLL-735 Dual Integrated Central Office Line Units (DICOLUs), eight PG-Flex
Plus
ALU-935 Asyn-
chronous Transfer Mode Central Office Line Units (ACOLUs), or four FLL-814 Flex Integrated Central Office Line
Units (FICOLUs) can be installed in the Field Shelf (
The PCS-822 contains eight 200 mechanics DS1 slots that provide up to 96 DS0s of Time Division Multiplex (TDM)
services and up to 128 PVCs for ATM services. These slots support external interfaces of T1, High-bit-rate Digital
Subscriber Loop (HDSL), or HDSL2. PCT-850 cards can also be placed in the T1 slots for feeding an external
DSX-1 directly into the
Multiplexer Unit (MUX).
Figure 1. Field Shelf Mounted in the Marconi NCAD16C Pedestal
Table 1. PCS-822 Card Types/System Types
Only 200 mechanics cards that use pin 27 for frame to ground connections should be used with the
PCS-822.
Entity
4/6 Channel
Systems
24 Channel
Systems
IAD and RAM Systems
Management Unit (MU) PMU-712
PMU-712
AMU-912 or PMU-712
Multiplex Unit (MUX)
PMX-744
PMX-744
AMX-943
Line Unit (LU)
PLL-735
FLL-814
ALU-935
Eight COLU Line
Unit Slots
Management Unit
and Multiplexer Unit
Slots
200 Mechanics Slots
Five-pin Protector Blocks
Fan Tray