![ADC HRU-419 HiGain User Manual Download Page 31](http://html1.mh-extra.com/html/adc/hru-419-higain/hru-419-higain_user-manual_2848162031.webp)
150-419-100-03>
Installation
HRU-419 List 1
September 25, 1998
23
M
AINTENANCE
AND
R
EMOTE
T
ERMINAL
The Maintenance and Remote terminal menus have five view-only
performance screens for viewing system performance.
describes the
function of each screen.
After the maintenance terminal has been properly configured, you can press
the
several times to invoke the autobaud feature. Based on your
configuration, one of the following two screens display.
Table 8.
Maintenance and Remote Terminal Menus
Screen
Function
View Span Status
Allows you to monitor the HDSL line between the
HLU and the HRU-419 span (non-doubler
applications), and the HLU, HDU and HRU-419,
Spans 1 and 2 (for one doubler applications), and
Spans 1, 2 and 3 (for two doubler applications).
Set Clock*
Allows you to set both the time and the date
parameters at the HLU, and to update the same
settings at the HRU-419.
System Settings
Allows you to view all system settings.
View Performance
Data
Allows you to view the Errored Seconds (ES) and
Unavailable Seconds (UAS) between the HLU and
the HRU-419 span (non-doubler applications), and
the available spans (doubler applications) in
15-minute intervals over a four-hour time period.
View Performance
History
Allows you to view the ES and UAS between the HLU
and the HRU-419 span (non-doubler applications)
and the available spans (doubler applications) in
24-hour intervals over a seven-day period.
View Alarm History
Allows you to view alarm conditions between the
HLU and the HRU-419 span (non-doubler
applications) and the available spans (doubler
applications).
(*) Set from the Maintenance Terminal menu only
SPACEBAR