ADC HI GAIN H2TU-C-388 LIST 4G Quick Installation Download Page 6

L

OOPBACK

 T

ESTING

Initiate loopback testing from the maintenance menus. The inband codes shown below can 
be sent by a test set.

        

  

Table 1.

GNLB Loopback Commands

Loopback

Inband Code

Description

NLOC

1111000

DSX-1 signal is looped back to the network at the H2TU-C.

NREM

1110000

DSX-1 signal is looped back to the network at the H2TU-R.

CREM

1111110

DS1 signal from customer is looped back to the customer at the H2TU-C.

CLOC

1111100

DS1 signal from customer is looped back to the customer at the H2TU-R.

SMJK

11000

DSX-1 signal is looped back to the network at the H2TU-R SmartJack module.

Loopdown

11100

Deactivates any of the above loopbacks.

Table 2.

LED Status and Functions

LED and Status

Function

DSL

OFF No power is applied to the H2TU-C.

Solid green Normal operation: HDSL2 span is synchronized without error.

Solid red HBER, MARG, or PWRF alarm is present at the H2TU-C.

Flashing red once every second HDSL2 loop is attempting synchronization.

ALM

OFF Normal operation: the DSX-1 signal is present at both the H2TU-R and 

H2TU-C.

Solid yellow RLOS is present at the H2TU-R.

Solid red LLOS is present at the H2TU-C.

DSX/DS1

Solid green Normal operation: the DSX-1 signal is error free.

Solid red LLOS, BPV, frame error, or CRC is present at the H2TU-C.

ESF/SF

OFF Unframed DSX-1 is present at the H2TU-C, unit set as unframed, or no 

DSX-1 is detected at the H2TU-C.

Solid yellow ESF frame formatting is present at the H2TU-C.

Flashing yellow once every second ESF frame formatting and frame error/CRC are present at the H2TU-C.

Solid green SF frame formatting is present at the H2TU-C.

Flashing green once every second SF frame formatting and frame error are present at the H2TU-C.

B8ZS/AMI

OFF No DSX-1 signal is present at the H2TU-C.

Solid yellow B8ZS is present at the H2TU-C.

Flashing yellow once every second B8ZS and excess zeros string are present at the H2TU-C.

Solid green AMI is present at the H2TU-C.

Flashing green once every second AMI and BPV are present at the H2TU-C.

LBK

OFF H2TU-C is not in loopback.

Solid yellow H2TU-C is in either NLOC or CREM (RLB).

To comply with the intrabuilding wiring requirements of GR-1089 
CORE, Section 4.5.9, the shields of the ABAM-type cables that 
connect the line unit  DSX-1 output ports to the cross-connect 
panel must be grounded at both ends.

Network

H2TU-C

H2TU-R

TLOS*

NLOC

CREM

CLOC

NREM

SMJK

* When enabled, TLOS is an automatic loopback

that occurs with an LOS at the remote DS1 input.

Downstream

Upstream

Customer
Premises

DS1

DSX-1

H0025-A

Table 3.

Maintenance Terminal Config Menu—Standard Options

 (a)

(a) Default settings are in bold.

Standard Option

Function

Loopback Timeout 
(LBTO)

Sets automatic cancellation of all loopbacks to NONE, 20 min, 60 min, or 
120 min after activation.

Loop Attenuation 
Threshold (LATT)

Determines the maximum loop attenuation (0 to 40 dB) before an alarm is 
declared. Zero disables the alarm. Default setting is 32 dB.

Margin Threshold 
(MARG)

Determines the minimum allowable margin (0 to 15 dB) below which a system 
alarm can occur. Zero disables the alarm. Default setting is 4 dB.

DS1 Frame Formatting 
(FRMG) 

AUTO = system searches DS1 transmission for SF or ESF frame pattern. 
SF = sets system for SF frame formatting.
ESF = sets system for ESF frame formatting.
UNFR = system functions as a transparent bit pipe.

DS1 Line Coding (DS1)

B8ZS = sets system for B8ZS line code. 
AMI = sets system for AMI line code.

H2TU-C  Equalization 
(EQL)

Sets the DSX-1 equalizer to: (0 to 132 ft.), 133 (133 to 265 ft.), 266 (266 to 
398 ft.), 399 (399 to 532 ft.), or 533 (533 to 655 ft.).

H2TU-R Line Buildout 
(RLBO)

Sets the DS1 receive level output toward the Customer Interface to 0 dB, 
-7.5 dB, or -15.0 dB.

Alarm Pattern (ALMP)

Enables an AIS or LOS output at the DS1 ports for LOSW or LOS DS1.

H2TU-R TLOS Loopback 
(TLOS)

Enables (ENA) or disables (DIS) a TLOS  loopback at H2TU-R for LOS at its 
DS1 input (if enabled at the H2TU-R).

Network Loopback 
Pattern (NLBP)

Enables the H2TU-R to transmit an AIS or LOS towards CI for any network 
loopback. 

Power Back Off Network 
(PBON)

The power output levels of the H2TU-C network unit toward the customer. 
Default (DEF) or enhanced (ENH).

Power Back Off Customer 
(PBOC)

The power output levels of the H2TU-R customer unit toward the network. 
Default (DEF) or enhanced (ENH).

Table 4.

Maintenance Terminal Config Menu—ADC Options

 (a)

(a) Default settings are in bold.

ADC Option

Function

Line Power Feed (PWRF)

Enables (ON) or disables (OFF) HDSL2 line power.

Remote Provisioning 
(RTPV)

Enables (ENA) or disables (DIS) remote provisioning.

Bipolar Violation 
Transparency (BPVT)

Enables (ENA) or disables (DIS) Bipolar Violation Transparency.

DS1 BER (DBER)

Enables (ENA) or disables (DIS) 24-hour DSX-1 BER alarm threshold.

HDSL2 BER Threshold 
(HBER)

Sets HDSL2 BER alarm threshold at 1E-6, 1E-7 or NONE.

Special Loopback Mode 
(SPLB)

Configures system for generic (GNLB) or special inband loopback command 
(A3LB).

SmartJack Loopback 
(LPBK)

Enables (ENA) or disables (DIS) SmartJack (SMJK) loopback commands.

Network AIS Pattern 
(NAIS)

If ALMP is set to AIS, determines which pattern is sent to the network when a 
remote LOS or AIS occurs. CI = AIS-CI sent to the network; AIS = AIS sent to 
the network.

Performance Report 
Messaging (PRM)

OFF = no enhanced Performance Report Messaging, SPRM = Supplemental 
PRM, NPRM = Network PRM, S + N = H2TU-R generates both SPRMs and 
NPRMs whenever possible.

RAI to RAI-CI towards 
NET (RACI)

Enables (ENA) or disables (DIS) conversion of a DS1 RAI signal (yellow alarm) 
received by the H2TU-R to an RAI-CI signal toward the network.

ESF-RAI to SF-RAI 
Overwrite (ROVR)

Enables (ENA) or disables (DIS) conversion of an ESF DS1 payload from the 
network with an embedded RAI pattern to an SF-RAI pattern toward the CI at 
the H2TU-R. CONV option must be set to FCON or ACON.

H2TU-R DS1 Frame 
Conversion (CONV)

OFF = framing determined by the DS1 FRMG option, ACON = autodetection of 
framing and potential frame conversion at the H2TU-R, FCON = autodetection 
of framing and forced frame format conversion at the H2TU-R.

Fractional T1 Mode (FT1)

Enables (ENA) or disables (DIS) system response to DDS latching loopback 
commands for fractional T1 applications, CP disconnect, and trouble 
indication. 

Copies of this publication or the user manual (LTPH-UM-1169-xx) 
can be downloaded from the ADC website at www.adc.com. To 
order a hard copy, please contact your sales representative.

 

Front Panel

Card-Edge Connector

106

105

104

103

102

101

100

DSX-1 OUT

DSX-1 IN

205

204

203

202

201

200

119

118

117

116

115

114

113

112

111

110

GND

GND

Frame GND

Fuse alarm*

Ring1

Tip1

Management bus

Ring

Tip

Factory burn-in

-48Vdc

219

218

217

216

215

214

213

212

211

210

209

208

207
206

109

108

107

* Fuse alarm is normally floating (0 to 80 Vdc max.) and

at -48 Vdc (10 mA max.) when activated.

HDSL2 Span

Ring

Tip

Craft port

List number

CLEI/ECI bar code label
(inside handle)

Handle

Maintenance Terminal Modem Settings
9600 baud
8 data bits
No parity
1 stop bit
Hardware flow control: OFF
Terminal emulation: VT100

DSX-1 access jacks

Connect standard test equipment.

LINE

Provides splitting jack access to
(IN) and from (OUT) the HDSL2 span
at the DSX-1 interface.

MON

Provides non-intrusive monitoring jack
access to (IN) and from (OUT) the
HDSL2 span at the DSX-1 interface.
Allows monitoring of the T1 payloads.

To access all system maintenance, provisioning

and performance screens, connect a standard

DB-9 terminal cable between the serial port

on a PC and the H2TU-C craft port.

Status LEDs

H0061-A

H2TU-C 388

DSL

LINE

I

N

I

N

O
U

T

O
U

T

ALM

DSX

DS1

ESF

SF

YEL

GRN

B8ZS

AMI

LBK

MON

DSX1

RS 232 DCE

L

Summary of Contents for HI GAIN H2TU-C-388 LIST 4G

Page 1: ...SIONING Perform these basic provisioning tasks 1 Connect a maintenance terminal to the craft port see front panel illustration inside and log on Press to refresh the logon screen if necessary Refer to...

Page 2: ...erform these basic provisioning tasks 1 Connect a maintenance terminal to the craft port see front panel illustration inside and log on Press to refresh the logon screen if necessary Refer to the onsc...

Page 3: ...erform these basic provisioning tasks 1 Connect a maintenance terminal to the craft port see front panel illustration inside and log on Press to refresh the logon screen if necessary Refer to the onsc...

Page 4: ...Alarm Pattern ALMP Enables an AIS or LOS output at the DS1 ports for LOSW or LOS DS1 H2TU R TLOS Loopback TLOS Enables ENA or disables DIS a TLOS loopback at H2TU R for LOS at its DS1 input if enable...

Page 5: ...dB Alarm Pattern ALMP Enables an AIS or LOS output at the DS1 ports for LOSW or LOS DS1 H2TU R TLOS Loopback TLOS Enables ENA or disables DIS a TLOS loopback at H2TU R for LOS at its DS1 input if enab...

Page 6: ...dB Alarm Pattern ALMP Enables an AIS or LOS output at the DS1 ports for LOSW or LOS DS1 H2TU R TLOS Loopback TLOS Enables ENA or disables DIS a TLOS loopback at H2TU R for LOS at its DS1 input if enab...

Page 7: ...SIONING Perform these basic provisioning tasks 1 Connect a maintenance terminal to the craft port see front panel illustration inside and log on Press to refresh the logon screen if necessary Refer to...

Reviews: