Monitoring System Activity and Performance
152-388-115-03, Issue 03
40
April 21, 2000
H2TU-C-388 List 1E
Alarm History at the HDSL2 Interface
shows the H2TU-C HDSL2 alarm history.
describes the alarms.
Figure 21.
H2TU-R DS1 Alarm History Screen
Table 18.
HDSL2 Alarm Descriptions
Screen Alarm
Description
To inhibit
LOSW
Loss of Sync Word—The HDSL2 loop has lost synchronization.
Cannot be inhibited.
MAL
Margin Alarm—The margin on the HDSL2 loop has dropped below the
minimum threshold value set for the system.
Set the Margin Alarm Threshold option
to 0 (zero).
LA
Loop Attenuation—The attenuation on the HDSL2 loop has exceeded
the maximum value set for the HDSL2 loop attenuation threshold.
Set the HDSL2 Loop Attenuation
Threshold option to zero.
HBER
Block Error Rate—The HDSL2 BER has exceeded the set threshold
limits of 10
- 7
or 10
-9
.
Select NONE for the HBER system
option.
SHORT
(a)
Indicates a short between the Tip and Ring of the HDSL2 pair.
Cannot be inhibited.
GND
(a)
The HDSL2 loop is grounded.
Cannot be inhibited.
OPEN
(a)
Indicates a line power open condition.
Cannot be inhibited.
(a) Appears only at the H2TU-C HDSL2 Interface.
Monitor
Performance
Event Log
Config
Inventory
Rlogon
Help
H2TU-C HDSL2 Alarm History
------------------------------------------------------------------------------
Alarm
First
Last
Status
Count
LOSW
03/16/00 00:00
03/16/00 00:45
ALARM
12
MAL
OK
0
LA
OK
0
HBER
03/16/00 00:37
03/16/00 00:45
OK
7
SHORT
OK
0
GND
OK
0
OPEN
OK
0
Press: C(l)ear Alarm History
------------------------------------------------------------------------------
Press <Space> to cycle through
Interface
: H2TU-C HDSL2
choices and <Enter> to view
Statistics :
Alarm History
ID: xxxx--xxxx--xxxx--xxxx
04/21/00 12:30:01
H2TU-C
System: Alarm