background image

SCP-FRE765-041-03H

Functional Description

FRE-765 List 4A

January 6, 2003

 13

 

Table 9. 

 Subscriber Termination

*

 

(*) The cable on the rear of the termination 

module is installed in connector P1 on the RT 
enclosure backplane.

(†) Shaded terminations used only with the 8 

Channel POTS Units.

Channel Unit

Subscriber 

Connector

Slot

Circuit

1

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

2

1

9

2

10

3

11

4

12

5

13

6

14

7

15

8

16

3

1

17

2

18

3

19

4

20

5

21

6

22

7

23

8

24

Summary of Contents for FRE-765

Page 1: ...SCP FRE765 041 03H Section PG FLEX TECHNICAL PRACTICE REMOTE TERMINAL ENCLOSURE Model List CLEI Code FRE 765 4A VAMRBN0L...

Page 2: ...consent of ADC Contents herein are current as of the date of publication ADC reserves the right to change specifications at any time without notice Information furnished by ADC is believed to be accu...

Page 3: ...ist 4A January 6 2003 USING THIS TECHNICAL PRACTICE Two types of messages identified by icons appear in the text Notes contain information about special circumstances Cautions indicate the possibility...

Page 4: ...Using This Technical Practice SCP FRE765 041 03H January 6 2003 FRE 765 List 4A...

Page 5: ...___________________________________ 7 Mounting 7 Chassis Ground Wiring 8 HDSL Auxiliary Power Bypass Pair Wiring 8 HDSL Pairs 10 Bypass Pair 11 Auxiliary Power Pairs 11 Subscriber Line Wiring 12 Cabli...

Page 6: ...SCP FRE765 041 03H ii January 6 2003 FRE 765 List 4A...

Page 7: ...erior View 1 2 Installing the Grommet 7 3 Installing the Ground Wire 8 4 COT or Field Shelf to FRE 765 RT Enclosure No Doublers 9 5 COT or Field Shelf to FRE 765 RT Enclosure 1 Doubler 9 6 COT or Fiel...

Page 8: ...SCP FRE765 041 03H iv January 6 2003 FRE 765 List 4A...

Page 9: ...nments 4 2 Channel Unit Circuit Utilization 4 3 FRE 765 List 4A Backplane Connectors 5 4 Connector P3 5 5 Connector P2 b 6 6 Power and Ground Line Unit Terminations 6 7 Grommet Hole Diameters 7 8 HDSL...

Page 10: ...SCP FRE765 041 03H vi January 6 2003 FRE 765 List 4A...

Page 11: ...closure can be pole or wall mounted and is environmentally sealed for outside plant installations Figure 1 FRE 765 List 4A RT Enclosure Interior View Features of the FRE 765 List 4A RT Enclosure inclu...

Page 12: ...air circuits must be protected with 3 mil carbon blocks or equivalent Subscriber circuits must also be protected with 3 mil carbon blocks or equivalent when these circuits are exposed to the outside p...

Page 13: ...our 4 circuits Ckt 1 through Ckt 4 are used for Tip and Ring terminations For channel units providing eight 8 circuits Ckt 1 through Ckt 8 are used for Tip and Ring terminations For a 24 channel syste...

Page 14: ...xiliary Power Line Unit Terminations on page 10 for Line Unit Terminations from the Backplane Ckt 1 Ckt 1 Ckt 1 Ckt 2 Ckt 2 Ckt 2 Ckt 3 Ckt 3 Ckt 3 Ckt 4 Ckt 4 Ckt 4 Not Ckt 5 Ckt 5 Ckt 5 Used Ckt 6 C...

Page 15: ...Terminations Table 8 HDSL Metallic Bypass and Auxiliary Power Line Unit Terminations on page 10 Power and Ground Line Unit Terminations Table 6 Power and Ground Line Unit Terminations on page 6 Table...

Page 16: ...29 4 WH BN BN WH 5 30 5 WH SL SL WH 6 31 6 RD BL BL RD 7 32 7 RD OR OR RD 8 33 8 RD GN GN RD 1 34 9 RD BN BN RD 2 35 10 RD SL SL RD 3 36 11 BK BL BL BK 4 4 37 12 BK OR OR BK 5 38 13 BK GN GN BK 6 39 1...

Page 17: ...les in the grommet 1 Select only one concentric knockout hole on the FRE 765 2 Remove the largest knockout so that the entire hole is open 3 Install the grommet from the outside of the FRE 765 Hint Ho...

Page 18: ...onnect the other end of the chassis ground wire to a suitable ground termination point ground rod or cold water pipe 4 Tighten the strain relief around the wire Figure 3 Installing the Ground Wire HDS...

Page 19: ...rth power pairs are wired to the same terminations as the first and second power pairs respectively on the COT or Field Shelf and the FRE 765 RT Enclosure These power pairs do not pass through the dou...

Page 20: ...terminations for HDSL Pair 2 from the COT 130 Vdc is simplexed on this line for powering the RT BYPASS Tip and Ring terminations for the metallic bypass pair to the COT PWR 1A Termination for auxiliar...

Page 21: ...termination 3 Use a cable tie to secure to the bracket near the cable entrance Auxiliary Power Pairs Follow these instructions when PG Flex is used with a doubler and see Figure 7 Installing HDSL Line...

Page 22: ...ines on page 12 1 Route the subscriber line cables through the bottom of the enclosure 2 Terminate the cables per Table 9 Subscriber Termination on page 13 3 Secure with a cable tie to the bracket nea...

Page 23: ...the rear of the termination module is installed in connector P1 on the RT enclosure backplane Shaded terminations used only with the 8 Channel POTS Units Channel Unit Subscriber Connector Slot Circui...

Page 24: ...SL lines are dry a Verify 0 Vdc between the Tip and Ring Tip and ground and Ring and ground of each of the HDSL pairs terminated at the FRE 765 b Verify a value greater than 100 k resistance between T...

Page 25: ...2 Call or write ADC s RMA Department to ask for an RMA number and any additional instructions Use the telephone number fax number or email address listed below Telephone 800 366 3891 Email Address rma...

Page 26: ...s address and the RMA Number you received from the RMA Department clearly on the outside of the carton and return to ADC DSL Systems Inc 14352 Franklin Ave Tustin CA 92780 7013 Attention RMA Number If...

Page 27: ...on If this equipment does cause harmful interfer ence to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfer...

Page 28: ...Gauge Ckt Circuit CO Central Office COT Central Office Terminal CU Channel Unit FCC Federal Communications Commission FRE PG Flex Remote Enclosure GND Ground HDSL High bit rate Digital Subscriber Line...

Page 29: ......

Page 30: ...World Headquarters ADC Telecommunications Inc 12501 Whitewater Drive Minnetonka Minnesota USA 55343 For Technical Assistance 800 366 3891 Sl 8H 1251768...