background image

A Special

Thank You...

Thank you for choosing an ADC

®

Diagnostix

TM

e-sphyg

TM

blood

pressure instrument. We're proud of the care and quality that
goes into the manufacture of each and every item that bears our
name.

Only the finest materials are used to assure you of a timeless
instrument designed for optimum performance.

You'll quickly appreciate the results; for you now own one of the
finest sphygmomanometers that money can buy.

With proper care and maintenance, your ADC blood pressure
instrument is sure to provide you with many years of depend-
able service.  Please read the following instructions and general
information, which will prove helpful in allowing you to enjoy
your ADC product.

Thank you for your patronage.  It is indeed our pleasure to serve
you. 

Sincerely,
American Diagnostic Corp.

©2005 AMERICAN DIAGNOSTIC CORP.

NAME/FUNCTION OF PARTS

Gauge Hang

Tab

Arm Cuff

Gauge

Backlight

Button

On / Off

Zeroing Button

Artery Mark

Air Tube and

Connector

Air Release Valve &

Inflation Bulb

Error Message:

Description:                   Solution:

ERROR MESSAGES

Err

Heartbeat rate

detection error.

The cuff was deflated
too rapidly. Keep the

deflation rate at

about 2-3 mmHg

per second.

EE

Press the “     ” button

to switch the unit off,

or the unit will auto-

matically switch off

after 60 seconds.

E3

Data Error.

Remove and rein-

sert the batteries. If

this error keeps

occurring, return

the device to your

local distributor or

service center. 

0I

The cuff was inflated

to a pressure over

300 mmHg.

Open the valve
immediately to

rapidly exhaust the

air in the cuff.

A Pressure of over

15mmHg remaining

for more than

3 minutes is detected.

 

 

 

 

 

 

Summary of Contents for Diagnostix e-sphyg

Page 1: ...onsequential damages Some states do not allow the exclusion or limitation of incidental special or consequential damages so this limitation may not apply to you To Obtain Warranty Service Send item s postage paid to ADC Attn Service Dept 55 Commerce Dr Hauppauge NY 11788 Please include your name and address daytime phone no proof of purchase a brief note explaining the problem and 2 00 to cover th...

Page 2: ...you for your patronage It is indeed our pleasure to serve you Sincerely American Diagnostic Corp 2005 AMERICAN DIAGNOSTIC CORP NAME FUNCTION OF PARTS Gauge Hang Tab Arm Cuff Gauge Backlight Button On Off Zeroing Button Artery Mark Air Tube and Connector Air Release Valve Inflation Bulb Error Message Description Solution ERROR MESSAGES Err Heartbeat rate detection error The cuff was deflated too ra...

Page 3: ...liability exceeding the most popular aneroid models While tradi tional mechanical gauges can be easily knocked out of calibration when dropped your digital gauge will remain accurate even when subjected to rough treatment With its helpful on screen calibration reminder you will be able to use your new digital gauge with confidence and with the knowledge that it will remain calibrated beyond the li...

Page 4: ...ncil directive 93 42 EEC EMC directive 89 336 EEC EN 1060 1 1995 Non invasive sphygmomanometers Part 1 General Requirements EN 1060 3 1997 Non invasive sphygmomanometers Part 3 supplementary requirements for electro mechanical blood pressure measuring systems ANSI SP10 To ensure the reliable operation of this sphygmomanometer use it in temperatures ranging from 50 F 10 C to 104 F 40 C The sphygmom...

Page 5: ...dder around the arm snugly and smoothly and engage adhesive strips To verify a correct fit check that the Index Line falls between the two Range Lines CALIBRATION OF THE DIGITAL GAUGE Gauge accuracy can be checked visually whenever it is switched on If the unit is used more than 10 000 times a calibration reminder message CAL will appear on the digital display Any digital gauge that displays this ...

Page 6: ...e Remove cuff BACKLIGHT CONTROL The default setting on your digital gauge is to have the back light on once the pressure is inflated over 30 mmHg and throughout the measurement process To switch the backlight off at any time press the button on the left side You will need to deactivate the backlight each time you power on the instrument CARE AND MAINTENANCE Storage After measurement wrap cuff arou...

Reviews: