background image

Spec 

Sheet

Website: www.adc.com

From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080 

Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website.

ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota  USA  55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously 
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may 
verify  product  specifications  by  contacting  our  headquarters  office  in  Minneapolis.  ADC  Telecommunications,  Inc. 
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features 
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer

106823AE  8/08  Revision  ©  2008, 2005, 2004  ADC Telecommunications, Inc.  All Rights Reserved

The Radiator II Below Ground HDSLx 8-Slot Repeater Housing is designed to withstand hostile 
conditions, improve thermodynamic performance and reliability of the outside plant electronics in  
50 percent less manhole space than traditional enclosures. It includes a 30-foot, 100-pair air core 
screened, dual armor cable stub.

ceNtRAL OFFIce

eLectRONIcS

cUStOMeR pReMISeS

eLectRONIcS

OSp

Repeaters

Repeaters

RADIAtOR

OSp

RADIAtOR

Specifications

Housing Construction, Lid:

  

Non-corrosive 18-gauge seamless, 316 stainless steel, painted white

Capacity: 

 

 Supports 8 single or a maximum of 6 double wide HDSL, HDSL4, 
G.SHDSL, T1, ISDN and DDS repeaters

Ambient Temperature Range:

  

–40˚F to +149˚F (–40˚C to +65˚C)

Relative Humidity:

  

100% when pressurized

Pressurization:

  

12 psi maximum – pressure relief valve

Security: 

 

V-band may be secured with a padlock

Dimensions: 

 

Diameter 12.5”, housing and mounting bracket together 14.25” high

Weight (without modules/cable stub):

  Approximately 28 lbs.

Mounting: 

 

Backboard or underground rack mount

Lightning Protection:

  

Three-element gas tube

Safety Standards Compliance:

 

Equipment tested and verified to comply with the following standards:

  GR 63-CORE:

 

Network Equipment-Building System (NEBS) Requirements 

 

GR 487-CORE:

 

Generic Requirements for Electronic Equipment Cabinets 

 

GR 950-CORE:

 

Generic Requirements for Optical Network Unit (ONU) Closures

  TR-TSY-000056:

 

Repeater Housings for T1, T1C, T1D, and T1G Carrier Systems

  FCC Part 15:

 

Electrical Safety

  Binational Standard:

 

 UL-60950/CSA C22.2 No. 950-95: Safety of Information  
Technology Equipment

O r d e r i n g   I n f o r m a t i o n

Description

  Catalog Number 

Radiator II 8-Slot Below Ground HDSLx Repeater Housing

 

  30’ air core stub, pressurized

  RAD-BA30-8

Reviews: