ADCP-50-304 • Issue 19 • June 1999 • Section 6: Installation
Page 6-9
© 1999, ADC Telecommunications, Inc.
4.3
Automatic Alarm Reset Jumper Installation
The automatic reset jumper must be installed before the module is installed in the chassis. Each
module with the alarming feature has automatic reset and store jumper contacts in the lower
right corner of the component side as shown in
. The alarm automatically resets when
the jumper is on the left set of contacts. The jumper may be stored (i.e., the alarm does not
automatically reset) on the right set of contacts.
Figure 6-7. Jumper Locations
ALARM
JUMPER
AUTOMATIC ALARM
RESET JUMPER
INTERLOCKED
GROUP JUMPER
1564-A