Gas Connections (per pocket):

Inlet connection ........ 1/2” N.P.T.
Inlet supply size ....... 1/2” Pipe (minimum)
Btu/hr input ............... 72,000 (18,143 kcal/hr)

Single-Phase Electrical Lead Connections

Black

+

Positive

White or Red

+

Neutral

or L2

Green

+

Ground

For 110V Applications

For 208-240V Applications

Single-Phase (1ø) Wiring Connections/Hookup

The electrical input connections on all single-phase (1ø)
gas dryers are made into the junction box located at the top
left rear area of the dryer (refer to page 7).

A ground wire is provided in the electrical box to connect
your service ground.

Gas Information ______________________

It is your responsibility to have all plumbing connections made
by a qualified professional to ensure that the gas plumbing
installation is adequate and conforms to local and state
regulations or codes.  In the absence of such codes, all
plumbing connections, materials, and workmanship must
conform to the applicable requirements of the National Fuel
Gas Code ANSI Z223.1-LATEST EDITION, or in Canada, the
Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural
Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION.

In Australia, the fuel gas code is AS 5601/AG 601, local
authority, gas, electricity, and any other relevant statutory
regulations.

IMPORTANT: 

Failure to comply with these codes or

ordinances, and/or the requirements stipulated in this
manual, can result in personal injury and improper
operation of the dryer.

Each dryer must have its own manual shutoff valve to provide
isolation of the dryer from the gas supply.

The dryer and its individual shutoff valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psig (3.5 kPa).  The dryer must be isolated
from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas
supply system at test pressures equal to or less than 1/2
psig (3.5 kPa).

Type of Gas

Manifold Pressure

*

In-Line Pressure

Natural

3.5 in

 

wc

6.0 - 12.0 in wc

8.7 mb

14.92 - 29.9 mb

Liquid

Propane

10.5 in wc

11.0 in wc

26.1 mb

27.4 mb

!

 WARNING

Fire or explosion could result due to failure of isolating
or disconnecting gas supply as noted.

Gas Supply

The gas dryer installation must meet the American National
Standard...National Fuel Gas Code ANSI Z223.1-LATEST
EDITION, or in Canada, the Canadian Installation Codes
CAN/CGA-B149.1 M91 (Natural Gas) or CAN/CGA-B149.2-
M91 (L.P. Gas) or LATEST EDITION, as well as local codes
and ordinances and must be done by a qualified
professional.

NOTE: 

Undersized gas piping will result in ignition

problems, slow drying, increased use of energy, and can
create a safety hazard.

The dryer must be connected to the type of heat/gas indicated
on the dryer data label.  If this information does not agree
with the type of gas available, do not operate the dryer.
Contact the reseller who sold the dryer or contact the
manufacturer.

IMPORTANT: 

Any burner changes or conversions must

be made by a qualified professional.

The input ratings shown on the dryer data label are for
elevations up to 2,000 feet (610 meters), unless elevation
requirements of over 2,000 feet (610 meters) were specified
at the time the dryer order was placed with the factory.  The
adjustment or conversion of dryers in the field for elevations
over 2,000 feet (610 meters) is made by changing each
burner orifice.  If this conversion is necessary, contact the
reseller who sold the dryer or contact the manufacturer.

IMPORTANT: 

This gas dryer is not provided with an

internal gas supply shutoff and an external gas supply
shutoff must be provided.

Technical Gas Data
Gas Specifications

IMPORTANT: 

Failure to isolate or disconnect the dryer

from supply as noted can cause irreparable damage to
the gas valve voiding the warranty.

Summary of Contents for AD-333

Page 1: ...s de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d incendie ou d explosion ou pour éviter tout dommage matériel toute blessure ou la mort Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareils ...

Page 2: ...__________________________________________ ____________________________________________________________________________________________________ Replacement parts can be obtained from your reseller or the ADC factory When ordering replacement parts from the factory you can FAX your order to ADC at 1 508 678 9447 or telephone your order directly to the ADC Parts Department at 1 508 678 9000 Please s...

Page 3: ...and or weather The wiring diagram for the dryer is located in the front electrical control box area Table of Contents _________________ Proposition 65 Use of this product could expose you to substances from fuel combustion that contain chemicals known to the State of California to cause cancer birth defects and other reproductive harm In the State of Massachusetts the following installation instru...

Page 4: ...rubber and also may be a fire hazard The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produce damage to the machine and harmful fumes A program should be established for the inspection and cleaning of lint in the burner area exhaust ductwork and area around the back of the dryer The frequency of inspection and cleaning can best be determined from e...

Page 5: ..._____________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ ______________________________________________________...

Page 6: ...TRUCK 30 33 VOLTAGE AVAILABLE 120 240V 1 3ø 2 3w 50 60 Hz APPROXIMATE NET WEIGHT 675 lb 306 kg APPROXIMATE SHIPPING WEIGHT 710 lb 322 kg AIRFLOW PER POCKET 60 Hz 400 cfm 11 3 cmm 50 Hz 340 cfm 9 6 cmm HEAT INPUT PER POCKET 72 000 Btu hr 18 143 kcal hr EXHAUST CONNECTION DIAMETER 8 20 3 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION PER POCKET 1 2 F N P T Specifica...

Page 7: ...dclaundry com 7 Specifications _____________________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation ...

Page 8: ...e installed on noncombustible floors only The dryer must not be installed or stored in an area where it will be exposed to water and or weather The dryer is for use in noncombustible locations The dryer must be installed with provisions for adequate air supply as noted in this manual refer to Fresh Air Supply Requirements section Clearance provisions must be made from noncombustible construction a...

Page 9: ...ews or other obstructions which will collect lint Additionally inspection doors should be installed at strategic points in the exhaust ductwork for periodic inspection and cleaning Inadequate exhaust facilities may cause high temperature limit switches or airflow switches to shut off the dryers Do not disable the switches which are provided for your safety Instead investigate the exhaust ducting A...

Page 10: ...ain duct run from the last dryer to where it exhausts to the outdoors is unusually long over 30 feet 9 1 meters or has numerous elbows more than one in it Single Dryer Venting 8 Inch Duct IMPORTANT A minimum exhaust duct size of 8 inches 20 3 cm must be used For an 8 inch 20 3 cm run where a maximum of two elbows are used refer to the illustration below the ductwork from the dryer outlet must not ...

Page 11: ...es grounding must conform to applicable requirements of the National Electrical Code ANSI NFPA NO 70 LATEST EDITION or in Canada the installation must conform to applicable Canada Standards Canadian Electrical Codes Parts 1 2 CSA C22 1 1990 or LATEST EDITION The ground connection may be to a proven earth ground at the location service panel For added personal safety when possible it is suggested t...

Page 12: ...a The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply system at test pressures equal to or less than 1 2 psig 3 5 kPa Type of Gas Manifold Pressure In Line Pressure Natural 3 5 in wc 6 0 12 0 in wc 8 7 mb 14 92 29 9 mb Liquid Propane 10 5 in wc 11 0 in wc 26 1 mb 27 4 mb WARNING Fire or explosion ...

Page 13: ... All components materials must conform to National Fuel Gas Code Specifications ANSI Z223 1 LATEST EDITION or in Canada CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 L P Gas or LATEST EDITION for General Installation and Gas Plumbing as well as local codes and ordinances and must be done by a qualified professional It is important that gas pressure regulators meet applicable pressure requir...

Page 14: ...dels be sure that all gas shutoff valves are in the open position Be sure all back guard panels and service box covers have been replaced Check the lint door to ensure that it is closed and secured in place Rotate the tumbler by hand to be sure it moves freely Preoperational Test __________________ All dryers are thoroughly tested and inspected before leaving the factory However a preoperational t...

Page 15: ...f service for a period of time the following must be performed Discontinue power to the dryer either at the external disconnect switch or the circuit breaker Discontinue the gas supply for gas models only Shut off external gas supply shutoff valve Service Parts Information __________ Service Service must be performed by a qualified trained technician service agency or gas supplier If service is re...

Page 16: ... frequency of cleaning can best be determined from experience at each location Maximum operating efficiency is dependent upon proper air circulation The accumulation of lint can restrict this airflow If the guidelines in this section are met an ADC dryer will provide many years of efficient trouble free and most importantly safe operation WARNING Lint from most fabrics is highly combustible The ac...

Page 17: ... on the data label affixed to the right side panel area at the rear of the dryer When contacting ADC please have the model number and serial number available 1 Model Number This describes the style of dryer and type of heat gas electric or steam 2 Serial Number Allows the manufacturer to gather information on your particular dryer 3 Type of Heat This describes the type of heat for your particular ...

Page 18: ...ADC Part No 112175 9 06 05 14 ...

Reviews: