ADC AD-30x2 Series Installation Manual Download Page 1

AD-30x2(R)(i)

Installation Manual

ADC Part No. 113019-7

WARNING: For your safety the
information in this manual must be
followed to minimize the risk of fire or
explosion and to prevent property
damage, personal injury or death.

— Do not store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch;
do not use any phone in your
building.

Clear the room, building or area of
all occupants.

Immediately call your gas supplier
from a neighbor’s phone.  Follow
the gas supplier’s instructions.

If you cannot reach your gas
supplier, call the fire department.

— Installation and service must be

performed by a qualified installer,
service agency or the gas supplier.

AVERTISSEMENT: Assurez-vous de

bien suivre les instructions données dans
cette notice pour réduire au minimum le
risque d’incendie ou d’explosion ou pour

éviter tout dommage matériel, toute
blessure ou la mort.

—Ne pas entreposer ni utiliser d’essence

ni d’autres vapeurs ou liquides
inflammables à proximité de cet

appareil ou de tout autre appareil.

—QUE FAIRE SI VOUS SENTEZ UNE

ODEUR DE GAZ:

Ne pas tenter d’allumer d’appareils.

Ne touchez à aucun interrupteur.  Ne
pas vous servir des téléphones se

trouvant dans le bâtiment.

Évacuez la pièce, le bâtiment ou la
zone.

Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.

Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service
des incendies.

—L’installation et l’entretien doivent être

assurés par un installateur ou un

service d’entretien qualifié ou par le
fournisseur de gaz.

American Dryer Corporation

88 Currant Road

Fall River MA 02720-4781 USA

Telephone: +1 (508) 678-9000  /  Fax: +1 (508) 678-9447

e-mail: [email protected]

www.adclaundry.com

Summary of Contents for AD-30x2 Series

Page 1: ...s de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incendie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Ne pas entreposer...

Page 2: ...___________________________________________ ____________________________________________________________________________________________________ Replacement parts can be obtained from your reseller or...

Page 3: ...ration R M A Return Material Authorization UL Underwriters Laboratory WARNING IMPORTANT You must disconnect and lockout the electric supply and the gas supply or the steam supply before any covers or...

Page 4: ...ubber and also may be a fire hazard The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produce damage to the machine and harmful fumes A program should...

Page 5: ...___________________________________________________________ ____________________________________________________________ NOTES _____________________________________________________ ___________________...

Page 6: ...UCK 36 42 VOLTAGE AVAILABLE 120 240V 1 2w 50 60 Hz APPROXIMATE NET WEIGHT 520 lb 236 kg APPROXIMATE SHIPPING WEIGHT 550 lb 249 kg AIRFLOW PER POCKET 60 Hz 450 cfm 12 74 cmm 50 Hz 375 cfm 10 6 cmm HEAT...

Page 7: ...bustible floors only The dryer must not be installed or stored in an area where it will be exposed to water and or weather The dryer is for use in noncombustible locations The dryer must be installed...

Page 8: ...duct for each dryer The duct should go as directly as possible to the outside air Avoid sharp 90 right angle turns in ducting use 30 or 45 angles instead The radius of the elbows should preferably be...

Page 9: ...elbows Refer to the illustration below IMPORTANT The dryer exhaust duct must not be connected to any gas vent chimney wall ceiling or concealing space of a building It is recommended that exhaust or b...

Page 10: ...bligation Separate circuit for top and bottom pocket 8 18 14 Grounding A ground earth connection must be provided and installed in accordance with state and local codes In the absence of these codes g...

Page 11: ...ulator Incoming supply pressure must be consistent between a minimum of 6 0 in WC 14 92 mb and a maximum of 12 0 in WC 29 9 mb pressure Electrical Connections Leads Black Positive White Neutral Green...

Page 12: ...e should be determined by the gas supplier NOTE Undersized gas supply piping can create a low or inconsistent pressure which will result in erratic operation of the burner ignition system Preparation...

Page 13: ...of water and nonflammable mild detergent and tumbling them in the tumbler to remove this coating Preoperational Instructions __________ Coin Models Microprocessor Controller Computer When the micropr...

Page 14: ...burner area with a dusting brush or vacuum cleaner attachment Warranty Information ________________ Warranty Registration Visit us at www adclaundry com and register all of your new dryers by clickin...

Page 15: ...a red L E D diagnostic indicator will flash An unlit red L E D diagnostic indicator indicates normal operation A lit green L E D diagnostic indicator indicates dryer controller is calling for heat an...

Page 16: ...ILSWITCH CLOSED FAULT Sail switch is closed should be open at the start of a cycle O O O SAIL SWITCH OPEN FAULT Sail switch remained open after the cycle started Should have closed BURNER HIGH LIMIT F...

Page 17: ...closed before starting SAIL SWITCH OPEN Sail switch failed to close after starting BURNER HI LIMIT Oven thermostat switch has opened EXHAUST HI LIMIT Tumbler thermostat switch has opened BURNER CONTRO...

Page 18: ...ADC Part No 113019 7 08 20 14...