Provisioning
150-432-100-02, Revision 02
20
July 18, 2002
HLU-432 List 1
describes the System Settings options and lists the corresponding front-panel display codes. Factory
default parameters appear in boldface type.
Table 8.
HLU-432 List 1 System Settings
System Settings
Screen Options
Front-Panel
Display
Code
Parameter
Description
Equalization
EQL
0
Sets the Equalizer to DSX-1 for 0 to 132 feet.
133
Sets the Equalizer to DSX-1 for 133 to 265 feet.
266
Sets the Equalizer to DSX-1 for 266 to 398 feet.
399
Sets the Equalizer to DSX-1 for 399 to 532 feet.
533
Sets the Equalizer to DSX-1 for 533 to 655 feet.
SmartJack Loopback LBPK
DIS
Configures the HiGain system to ignore all inband SmartJack loopback
commands.
ENA
Enables the HiGain system to recognize all inband SmartJack loopback
commands.
Special Loopback
SPLB
GNLB
Configures the HiGain system to respond to the generic (3/4-in-7) inband
loopback codes.
A1LB and
A2LB
Configures the HiGain system to respond to the inband loopback codes of the
Teltrend addressable repeater.
A3LB
Configures the HiGain system to respond to the inband loopback codes of the
Wescom addressable repeater.
A4LB
Configures the HiGain system to respond to the inband loopback codes of the
Wescom Mod 1 addressable repeater.
A5LB
Configures the HiGain system to respond to the inband loopback codes of the
Teltrend Mod 1 addressable repeater.
Power
PLEV
DIS
Disables powering to the HDSL pair.
(See
.)
LOW
Keeps the HDSL line voltage at -135 Vdc maximum for all applications.
AUTO
Allows the HDSL line voltage to automatically switch between -135 Vdc
maximum for non-doubler applications and ±112 Vdc for doubler
applications.
HIGH
Forces the HDSL line voltage to ±112 Vdc for all applications.
ZBTSI
ZBTS
ON
Tells the HiGain system that the ESF frame is operating in its Zero-Byte
Timeslot Interchange (ZBTSI) mode.
OFF
Tells the HiGain system that the ESF frame is operating in its normal
non-ZBTSI mode.
BER Alarm
Threshold
BERT
1E-6
Activates (closes) the system alarm relay contacts on pins 20 and 21 of the
card-edge connector and flashes the red Status LED when the BER exceeds
10
-6
.
(See
.
1E-7
Activates (closes) the system alarm relay contacts on pins 20 and 21 of the
card-edge connector and flashes the red Status LED when 10
-6
> BER >10
-7
.
NONE
Prevents generation of a system alarm due to BER.
Loopback Timeout
LBTO
NONE
Disables automatic time-out cancellation of all loopbacks.
20
Sets automatic cancellation of all loopbacks to 20 minutes after initiation.
60
Sets automatic cancellation of all loopbacks to 60 minutes after initiation.
120
Sets automatic cancellation of all loopbacks to 120 minutes after initiation.
Alarm
ALM
DIS
Opens the system alarm relay contacts if closed, and disables activation of the
system alarm relay when a system alarm condition occurs.
ENA
Enables activation of the system alarm relay when a system alarm condition
occurs.