150-432-100-02, Revision 02
Provisioning
HLU-432 List 1
July 18, 2002
13
Maintenance Terminal Main Menu
shows the Maintenance Terminal Main Menu from which you can access system administration screens.
The function of each screen selection is listed in
. To access a screen, press the letter shown next to the
menu item.
Figure 3.
Maintenance Terminal Main Menu
Table 4.
Maintenance Terminal Screens
Press
Key
To View Screen
Screen Description
See page:
View Span Status
Provides access to subscreens that allow you to monitor the HDSL and T1
line status between the HLU and the HRU.
Set Clock
Allows you to set both the time and the date parameters at the HLU and to
update the same settings at the HRU.
System Settings
Allows you to set all user options.
Loopback Mode
Provides access to a subscreen that allows you to enable and disable
loopbacks at both the network and customer side.
View Performance Data
Provides access to subscreens that allow you to view the Errored Seconds
(ES) and Unavailable Seconds (UAS) between the HLU and the HRU in
15-minute intervals over a 4-hour time period per screen for a total of
24 hours (6 screens).
View Performance History
Provides access to subscreens that allow you to view the ES and UAS
between the HLU and the HRU in 24-hour intervals over a 31-day period.
View Alarm History
Provides access to subscreens that allow you to view alarm conditions
between the HLU and the HRU.
View System Inventory
Allows you to enter a unique circuit ID (up to 24 alphanumeric
characters).
View Troubleshooting
Provides a graphical analysis of the circuit and identifies problem areas
HI-GAIN HLU-432 MAINTENANCE TERMINAL MAIN MENU (ver V7.3L-1)
CIRCUIT ID#:
A. VIEW SPAN STATUS
B. SET CLOCK
C. SYSTEM SETTINGS
D. LOOPBACK MODE: NONE
E. VIEW PERFORMANCE DATA
F. VIEW PERFORMANCE HISTORY
G. VIEW ALARM HISTORY
H. VIEW SYSTEM INVENTORY
I. VIEW TROUBLESHOOTING
A
B
C
D
E
F
G
H
I