L-862S Stop Bar Elevated Light
96A0246 Rev. G
Installation
© ADB Airfield Solutions All Rights Reserved
14
2.3.7 Optional Stake
Installation
This subsection provides instructions for optional stake mounting. The light fixture is mated
with a 30-inch (762-mm) steel stake with a fitting attached at the top to receive the male
thread of the frangible coupling. Stake mounting requires transformers, cables, and
connectors that are designed for direct earth burial.
To install a stake, perform the following procedure:
1. See Figure 4. Install the stake (6) in 6-inch (152.4-mm) diameter holes at a depth of 30
inches (762 mm) so that the mounting hub of the stake is level.
Figure 4:
Stake Mounting
CAUTION
Do not drive stakes. Driving a stake may damage the stake and cause light fixture misalignment.
Refer to FAA specification AC 150/5340-30.
1. Frangible Column and
Disconnect Plug
4. Connectors
7. Concrete Anchor (Recommended 6
x 6 x 12-in.)
2. Stake Hub
5. 5 KV, L-824 Cable
8. Optional Bare Copper Counterpoise
Wire
3. Cable Connector Support
6. Metal Stake (30 in.)
9. L-830 Transformer
1
4
5
6
7
8
9
2
3