4.2 Replacing LED Mounting Assembly

Disconnect the power to the light assembly and remove the entire assembly from the location site. Unscrew and remove the

glassware assembly from the top of the obstruction light assembly. See.

Figure 3

Note

The individual LEDs are not replaceable. The entire LED mounting assembly must be replaced.

Lift the LED mounting assembly out of the fixture housing and locate and pull off the two-pin quick-disconnects on the PCB

assembly. Connect the new LED assembly leads to the PCB. See 

Figure 4

Note

Insure that the two leads do not become pinched when placing the LED assembly back into the housing and the

glassware assembly is screwed back onto the housing.

Reinstall the glassware assembly on to the top of the housing. Reinstall the repaired fixture back at the site location.

Figure 4: LED Mounting Assembly (LED Lead Quick-disconnect)

LED Assembly

Quick 
Disconnect

4.3 Replacing LED PCB Assembly

Disconnect the power to the light assembly and remove the entire assembly from the location site. Unscrew and remove the

glassware assembly from the top of the obstruction light assembly. See 

Figure 7.

L-810(L) SBOL - Steady Burning LED Obstruction Light
Maintenance and Repair

12
Copyright 

©

 ADB Safegate, All Rights Reserved

Summary of Contents for L-810(L) SBOL

Page 1: ...L 810 L SBOL Steady Burning LED Obstruction Light User Manual 96A0328 Rev J 2018 06 26 ...

Page 2: ......

Page 3: ...d are guaranteed to be merchantable and fit for the ordinary purposes for which such products are made ADB SAFEGATE L858 Airfield Guidance Signs are warranted against mechanical and physical defects in design or manufacture for a period of 2 years from date of installation per FAA AC 150 5345 44 applicable edition Note See your sales order contract for a complete warranty description All Products ...

Page 4: ...replacement parts or accessories Failing to make sure that auxiliary equipment complies with approval agency requirements local codes and all applicable safety standards if not in contradiction with the general rules Using materials or auxiliary equipment that are inappropriate or incompatible with your ADB SAFEGATE equipment Allowing unskilled personnel to perform any task on or with the equipmen...

Page 5: ...Burning Obstruction Light 5 2 2 2 Mounting Port 7 2 2 3 L 810 Obstruction Light Required Equipment 7 3 0 Installation 9 3 1 Introduction 9 3 2 Unpacking 9 3 3 Installation 9 3 4 Placement 9 3 5 Wiring 10 4 0 Maintenance and Repair 11 4 1 Replacing Lens 11 4 2 Replacing LED Mounting Assembly 12 4 3 Replacing LED PCB Assembly 12 5 0 Parts 15 5 1 Spare Components 16 A 0 SUPPORT 19 A 1 ADB Safegate we...

Page 6: ...L 810 L SBOL Steady Burning LED Obstruction Light TABLE OF CONTENTS vi Copyright ADB Safegate All Rights Reserved ...

Page 7: ...o observe this warning may result in personal injury death or equipment damage ARC Flash may cause blindness severe burns or death WARNING Wear personal protective equipment Failure to observe may result in serious injury WARNING Do not touch Failure to observe this warning may result in personal injury death or equipment damage CAUTION Failure to observe a caution may result in equipment damage Q...

Page 8: ...ecified by applicable safety regulations If safety devices must be removed for installation install them immediately after the work is completed and check them for proper functioning prior to returning power to the circuit Failure to follow this instruction can result in serious injury or equipment damage Additional Reference Materials Important Information IEC International Standards and Conformi...

Page 9: ...ety devices as specified by applicable safety regulations If safety devices must be removed for installation install them immediately after the work is completed and check them for proper functioning Route electrical wiring along a protected path Make sure they will not be damaged by moving equipment Never operate equipment with a known malfunction Do not attempt to operate or service electrical e...

Page 10: ...ial as the cabinet by touching a conductive earthed part of the cabinet Electronic modules or components must not be brought in contact with highly insulating materials such as plastic sheets synthetic fiber clothing They must be laid down on conductive surfaces The tip of the soldering iron must be grounded Electronic modules and components must be stored and transported in conductive packing Fai...

Page 11: ...2 2 1 LED Steady Burning Obstruction Light Compliance with Standards FAA L 810 L AC 150 5345 43 Current Edition and the FAA Engineering Brief No 67 ETL Certified ICAO Annex 14 Vol 1 para 6 3 Type A B Uses FAA K 810 L ICAO Steady burning red light fixture marking all fixed obstructions to eliminate air navigational hazards Features Average individual LED life of 100 000 hours Very low power rating ...

Page 12: ...nditions Temperature 40 F to 131 F 40 C to 55 C Humidity 0 to 100 Wind speeds Up to 150 mph 240 kph Electrical Supply Single with heater 120 VAC 22 W 29 VA Single without heater 95 264 VAC 7 W 14 VA Energy Cost Savings SBOL fixture results in a significant reduction in energy costs Electrical Variant LED Fixture Load Incandandescent Tungsten Halogen Load Energy Savings 95 264 VAC 14 VA 116 VA 120 ...

Page 13: ...ipment that is supplied Refer to Table 2 for required equipment that is not supplied Refer to the Parts section for part numbers Table 1 Required Equipment Supplied Description Quantity Note L 810 obstruction light 1 Instruction manual 1 A NOTE A Additional copies of manual are available on ADBs Web site Table 2 Required Equipment Not Supplied Description Quantity Note Wire input power 18AWG As re...

Page 14: ...L 810 L SBOL Steady Burning LED Obstruction Light L 810 SBOL 8 Copyright ADB Safegate All Rights Reserved ...

Page 15: ...t damage If you note any damage to any equipment file a claim with the carrier immediately The carrier may need to inspect the equipment 3 3 Installation This subsection provides installation instructions for L 810 obstruction light fixtures 3 4 Placement The placement and number of L 810 light fixtures required to adequately mark an obstruction for any approaching aircraft is determined by Height...

Page 16: ...val for servicing Figure 2 Wiring Connections BROWN WIRE AC WHITE WIRE DC CORDSET ASSY GREEN WIRE BLUE WIRE AC BLACK WIRE DC FROM 44A6662 HEATER 120 VAC HEATER 95 264VAC PCB VIEW D SBOL XX21 L N E 1 2 LOCKING NUT 44A6477 1 1400 PCB ASSY LED UNIV AC PWR SUPPLY 1400mA 95 260V BLUE WIRE AC BLACK WIRE DC BROWN WIRE AC WHITE WIRE DC GREEN WIRE 12VDC VIEW C SBOL XX4X SBOL XX3X 24 48VDC SBOL XX20 95 264V...

Page 17: ...onnect 4 1 Replacing Lens To replace a broken or cracked glassware unscrew the threaded lock ring and remove the glassware assembly from the top of the obstruction light housing See Figure 3 Remove the two button head screws that hold the lens attachment ring in place and then lift off the glassware Remove the rubber seals and discard the broken or cracked glassware Note When replacing the glasswa...

Page 18: ...4 Note Insure that the two leads do not become pinched when placing the LED assembly back into the housing and the glassware assembly is screwed back onto the housing Reinstall the glassware assembly on to the top of the housing Reinstall the repaired fixture back at the site location Figure 4 LED Mounting Assembly LED Lead Quick disconnect LED Assembly Quick Disconnect 4 3 Replacing LED PCB Assem...

Page 19: ...sconnects J1 and J2 on the PCB assembly if used See Figure 7 Disconnect the cordset wires shown in Figure 6 if used Figure 6 Power Supply and Ground Lead Connections Re connect the power leads to the new LED PCB assembly and reconnect the LED leads to the PCB Insert the PCB assembly back into the housing and also reinstall the LED mounting assembly onto the housing Torque the screws to 8 10 in lbs...

Page 20: ...L 810 L SBOL Steady Burning LED Obstruction Light Maintenance and Repair 14 Copyright ADB Safegate All Rights Reserved ...

Page 21: ... 1 Photocell IR 0 Without IR 1 IR and visible light output Arctic Option 0 Without arctic option 1 With arctic option2 Flashing 0 No flash 1 Flashing 30 flashes per minute 3 Notes 1 Fixture without heater is designed to operate from 95 VAC min to 277 VAC max 50 60 Hz 2 When powered by a parallel circuit heater is designed for use at only 120 VAC 10 50 60 Hz 3 Not ETL Certified OBSL X X X X X X X X...

Page 22: ...R SUPPLY 700mA 95 260V 44A6477 1 0701 LUBRICATE THREADS 67A0048 ANTI SEIZE COMPOUND 88A2146 1 HOUSING 1 NPT CONDUIT MOUNTING 88A2146 HOUSING 1 EMT CONDUIT MOUNTING 64A0173 8 1 4 20 X 1 2 Hex Head Stainless 44A6576 30 CORDSET ASSY FAA ICAO SBOL AC 44A6576 31 CORDSET ASSY FAA ICAO SBOL DC 73A0136 31 L823 CORDSET STYLE 6 LED ELEVATED 1 2 LOCKING NUT 89A0163 7 18AWG UL1015 16 30 GRN Y PCB 64A0198 8 41...

Page 23: ...C ATTACH BLACK WIRES DC 70A0671 3 CONDUCTOR COMPACT CONNECTOR 70A0671 3 CONDUCTOR COMPACT CONNECTOR 70A0175 4 TERM RING 22 18 AWG 10 INSUL 44A6396 2 DUAL SBOL BASE ASSEMBLY HORIZONTAL MOUNT 44A6396 1 DUAL SBOL BASE ASSEMBLY VERTICAL MOUNT SBOL 2120 SBOL 1120 SBOL ICAO RED BTM MT 95 260V NO ARC SBOL L810 RED BTM MT 95 260V NO ARC 96A0328 Rev J 2018 06 26 17 Copyright ADB Safegate All Rights Reserve...

Page 24: ...L 810 L SBOL Steady Burning LED Obstruction Light Parts 18 Copyright ADB Safegate All Rights Reserved ...

Page 25: ...ll When you have an airfield lighting or system control system problem it is our goal to support airfield maintenance staff as quickly as possible To support this effort we ask that you have the following information ready before calling The airport code If not with an airport then company name prefer customer id number Contact phone number and email address Product with part number preferable or ...

Page 26: ...ier components and sub contractor operations ADB Safegate offers a recycling program for our products to all customers worldwide whether or not the products were sold within the EU ADB Safegate products and or specific electrical and electronic component parts which are fully removed separated from any customer equipment and returned will be accepted for our recycling program All items returned mu...

Page 27: ...adbsafegate com ADB SAFEGATE Malmo ADB Safegate Sweden Address Djurhagegatan 19 SE 213 76 Malmö Sweden Phone Fax Contact Tel 46 0 40 699 17 00 Fax 46 0 40 699 17 30 Email marketing adbsafegate com Internet www adbsafegate com ADB Safegate Airfield Technologies Ltd China ADB Safegate China Address Unit 603 D Block CAMIC International Convention Center No 3 Hua Jia Di East road ChaoYang district Bei...

Page 28: ......

Reviews: