L-804 Elevated Runway Guard Light
96A0218 Rev. X
Installation
© ADB bvba All Rights Reserved
14
2.3.6 Installing Coupling
(Unmonitored)
This subsection describes how to install the coupling for the current and voltage driven
unmonitored versions of the RGL.
2.3.6.1 Current Driven
Unmonitored RGL
See Figure 9 in the Wiring Schematics section for the current driven unmonitored wiring
schematic. See Figure 5. To install the coupling for the current driven unmonitored version,
plug the L-830 transformer secondary cordset (2) into the 2-pin L-823 connector (1).
Figure 5:
L-804 Coupling (Monitored and Unmonitored Versions)
2.3.6.2 Voltage Driven
Unmonitored RGL
See Figure 10 in the Wiring Schematics section for the 120 V and the 220-240 V voltage
driven unmonitored wiring schematics.
To install the coupling for the voltage driven unmonitored version, perform the following
procedure:
1. See Figure 5. Plug the 2-pin L-823 cable (1) into the L-823 receptacle (2).
2. Wire the free ends to the proper voltage source.
2.3.7 Installing Coupling
(Monitored)
This subsection describes how to install the coupling for the current and voltage driven
monitored versions of the RGL.
2.3.7.1 Current Driven
Monitored RGL
See Figure 9 in the Wiring Schematics section for the current driven monitored wiring
schematic.
To install the coupling for the current driven monitored version RGL, perform the following
procedure:
1. See Figure 5. Plug the 5-pin cordset cable (3) into the 5-pin harness (4).
2. Wire the monitor leads (orange, red, and green) to the monitor circuit.
2.3.7.2 Voltage Driven
Monitored RGL
See Figure 11 in the Wiring Schematics section for the 120 V and the 220-240 V voltage
driven monitored wiring schematics.
To install the coupling for the voltage driven monitored version RGL, perform the following
procedure:
1. See Figure 5. Plug the 5-pin cordset cable (3) into the 5-pin harness (4).
2. Connect the black and white wires to the proper voltage source.
3. Wire the monitor leads (orange, red, and green) to the monitor circuit.
Unmonitored Version
Monitored Version
1
L-823 Cordset (2-Pin)
3
L-823 Cordset (2-, 4-,or 5-Pin)
2
L-830 Secondary Cordset
(Shown) or L-823 Direct Lamp
Access Harness (Provided)
4
Wiring Harness