Special operation mode
www.adblighting.com
User Manual - page 7
Issue
2.0
4. Special operation mode
4.1 Remote reset address
If during normal operation the positioning of the gel string is incorrect, it is possible to bring it
back to the correct position by sending a RESET signal from a control console. This function
is especially useful if the unit is installed in a difficult to reach position. In order to be reset
from a console, the unit must receive a signal of FULL intensity level, maintained for a period
of more than 1 second at the Remote Reset Address.
Note: The factory-set default RESET address is 000. This effectively disables the Remote
RESET function because DMX does not support address 000).
Remote reset address - setup (999)
Set the address switches to «999», and press the «TEST» button to enter this mode. The
«signal» LED will then flash at 10 times per second. Set the desired RESET address and
press the «TEST» button again to confirm this address. The unit will then reset.
Remember to set the address switches back to the normal operation address, and
then switch the unit off and on again, or the unit will not operate properly.
Beware that
WARP/M
remaps the changers address. The changer becomes a part of the
WARP/M
personality. External 3 become for example reset. (8 external parameters
available on
WARP/M
)
4.2 Auto trace mode (8XY)
The unit steps through each colour continuously from the first to the last colour and then
back to the first one. Set the address switches to 8XY and press the «TEST» button to enter
this mode. The value XY adjusts the speed of each stepping, the smaller the value, the faster
the stepping. «X» represents the speed of movement from starting end to the final end while
«Y» represents the speed of movement from the final end to starting end. When the value
XY is changed, it is necessary to press the «TEST» button or turn POWER OFF and then
ON to make the change effective.
4.3 Gel string movement speed setting (9XX)
16 different levels
of
speed
of
the gel string are available on
CC/WARP
changers. Set the
address to 9XX and press the «TEST» button to set the speed. The value XX (00-15) adjusts
the speed
of
the gel string movement, the smaller the value, the faster the speed.
For example the speed
of
the gel string ranges from 1.5s to 20s.
Remember to set the address switches back to the normal operation address, and
then switch the unit off and on again, or the unit will not operate properly.
4.4 Restore to factory default setting (600)
Set the address to 600 and press the TEST button to restore the factory default settings.
Factory default settings
Remote Reset Function
Disable
Gel string Movement Speed
Maximum
Summary of Contents for CC/W
Page 1: ...M 6043 1106 06 043 Lighting Technologies User Manual Issue 2 0 WARP Colour Changer CC W ...
Page 2: ......
Page 4: ...Product overview User Manual page 2 www adblighting com Issue 2 0 1 Product overview ...
Page 15: ...www adblighting com User Manual page 13 Issue 2 0 8 Personal Notes ...
Page 16: ......