![ADB Safegate RELIANCE Omni 1-Dome User Manual Download Page 51](http://html.mh-extra.com/html/adb-safegate/reliance-omni-1-dome/reliance-omni-1-dome_user-manual_2847420051.webp)
Figure 24: Pressure Relief Screw
A
B
A = Inner pan cover
B = Pressure release screw
Figure 25: Pressure Test Fitting Assembly
3. Attach the shop airline to the lock hose plug sleeve (2 in
4. Pressurize to 20 psi.
5. Submerge the pressure test fitting in a water tank.
Check for air bubbles. Air bubbles indicate a leak.
6. Locate the leak source, depressurize, replace the seal that is leaking, reassemble, and retest by following steps 4 and 5.
If leak is fixed, depressurize and reinstall the pressure release screw (1 in
Go to
to finish.
UM-5073, Rev. 1.0, 2021/07/13
41
Copyright
©
ADB SAFEGATE, All Rights Reserved
Summary of Contents for RELIANCE Omni 1-Dome
Page 1: ...RELIANCE Omni 1 Dome 8 inch User Manual UM 5073 Rev 1 0 2021 07 13 ...
Page 2: ......
Page 8: ...RELIANCE Omni 1 Dome List of Figures viii Copyright ADB SAFEGATE All Rights Reserved ...
Page 10: ...RELIANCE Omni 1 Dome List of Tables x Copyright ADB SAFEGATE All Rights Reserved ...
Page 20: ...RELIANCE Omni 1 Dome General Information 10 Copyright ADB SAFEGATE All Rights Reserved ...
Page 26: ...RELIANCE Omni 1 Dome Installation 16 Copyright ADB SAFEGATE All Rights Reserved ...
Page 28: ...RELIANCE Omni 1 Dome Operation 18 Copyright ADB SAFEGATE All Rights Reserved ...
Page 52: ...RELIANCE Omni 1 Dome Maintenance 42 Copyright ADB SAFEGATE All Rights Reserved ...
Page 54: ...RELIANCE Omni 1 Dome Troubleshooting 44 Copyright ADB SAFEGATE All Rights Reserved ...
Page 60: ...RELIANCE Omni 1 Dome POWER TABLE 50 Copyright ADB SAFEGATE All Rights Reserved ...
Page 62: ...RELIANCE Omni 1 Dome CABLE LOSS 52 Copyright ADB SAFEGATE All Rights Reserved ...
Page 66: ......