8.0 Troubleshooting
WARNING
• • Allow only qualified personnel to perform the following tasks. Observe and follow the safety
instructions in this document and all other related documentation.
• • Make sure power to the L-854 has been disconnected before attempting to service the Radio
Control Equipment.
Failure to follow these warnings may result in serious injury or equipment damage.
Refer to
. This section provides troubleshooting information for the L-854 Radio Control
Equipment.
Table 11: L-854 Radio Control Equipment Error Codes
Code
Description
Solutions
REQ SET
Unable to set tuner frequency
Replace Radio Control Board
FRQ LOAD
Unable to load the frequency assignment
from Non-Volatile Memory (Record can not
be found)
Replace Radio Control Board
TNR INIT
Unable to initialize the tuner (typically an
internal processor error)
Replace Radio Control Board
DSP INIT
Unable to initialize the display board
Replace Radio Display Board
RTC INIT
Unable to initialize the RTC chip
Replace Radio Control Board
ROM INIT
Unable to initialize the Nonvolatile memory
Replace Radio Control Board
A/D FAIL
The A/D Converter has failed
Replace Radio Control Board
ROM CKSM
ROM Checksum failure
Replace Radio Control Board
Table 12: L-854 Radio Control Equipment Warning Codes
Code
Description
Solutions
FRQ LOCK
The synthesizer is not indicating that it is
locked to it’s assigned frequency
Replace Radio Control Board
FRQ SAVE
Unable to save the assigned frequency to
non-volatile memory
Replace Radio Control Board
RTC SAVE
Unable to save to the RTC chip. The power
outage logic won’t restore the commanded
lighting state
Replace Radio Control Board
RTC LOAD
Unable to load data from the RTC chip
Replace Radio Control Board
LOW 5V
5 volt power is below 4.7V DC
Replace Power Supply Board
HIGH 5V
5 volt power is above 5.3V DC
Replace Power Supply Board
LOW 3.3V
3.3 volt power is below 3.0V DC
Replace Power Supply Board
HIGH 3.3V
3.3 volt power is above 3.6V DC
Replace Power Supply Board
96A0390, Rev. K, 2019/02/01
29
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for L-854
Page 1: ...L 854 Radio Control Equipment RCE Type I Style A User Manual 96A0390 Rev K 2019 02 01 ...
Page 2: ......
Page 6: ...L 854 Radio Control Equipment TABLE OF CONTENTS vi Copyright ADB Safegate All Rights Reserved ...
Page 18: ...L 854 Radio Control Equipment Options 12 Copyright ADB Safegate All Rights Reserved ...
Page 32: ...L 854 Radio Control Equipment Operation 26 Copyright ADB Safegate All Rights Reserved ...
Page 34: ...L 854 Radio Control Equipment Maintenance 28 Copyright ADB Safegate All Rights Reserved ...
Page 48: ......