5.4.1 ACE2 Cable Entry
Note
All conduit and wiring must only enter the ACE2 enclosure through the bottom or through the top access plate. This
facilitates quick maintenance and replacement of the ACE2 unit.
DO NOT blow out enclosures because metal shavings can damage the electronics.
Figure 18: Combo Box-Mount, Interior Drawing
There are six knockouts each in the top and in the bottom of the enclosure walls for one inch EMT metal conduit fittings for
wires and fiber optic cables. See
for dimensions in inches, and see
for routing. Power and
ACE-to-ACE communication wiring must be in separate conduits.
Figure 19: Combo Box-Mount, Bottom View
96A0357, Rev. G, 2019/11/08
25
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for ACE2
Page 1: ...Advanced Control Equipment ACE2 User Manual 96A0357 Rev G 2019 11 08 ...
Page 2: ......
Page 18: ...Advanced Control Equipment ACE2 Introduction 12 Copyright ADB Safegate All Rights Reserved ...
Page 42: ...Advanced Control Equipment ACE2 Parts 36 Copyright ADB Safegate All Rights Reserved ...
Page 46: ......