ADATIS UP Series Mounting And Installation Manual Download Page 7

 

Adatis GmbH & Co.KG 

 

page 7 of 8 

3

 

Getting started 

The terminals of the UP series are configured via the WEB interface. In order to enroll users 
at the terminals, they must first be created in the personnel database of the WEB interface 
by entering a PIN code. 

 

Default IP-address of the terminal: 

192.168.2.81

 

 

Default Login data for the web interface: 

Username: 

admin 

Password: 

1234 

 

 Opening the enrollment area of the UP terminals  

Enrollment area for face recognition: 

Enrollment card green (FaceUP only)

 

Enrollment area for RFID cards: 

Enrollment card red 

 

Further information about operation and configuration of the UP series can be found in the 
instructions on our homepage 

www.adatis.com

 for download. 

4

 

Mounting 

The UP series is designed for installation in 55 mm standard switch programs and is 
intended for indoor use. 

Recommended mounting height: approx. 164.5 cm centre of flush-mount box  

 

 

 

 

 

 

 

 

ca. 164,5 cm

approx. 164.5 cm 

Summary of Contents for UP Series

Page 1: ...Adatis GmbH Co KG page 1 of 8 UP Series Mounting and installation manual Version 0 1 Autor cschardt Datum 20 12 2018 Log V0 1 ...

Page 2: ...contents 1 SCOPE OF DELIVERY 3 2 CONNECTIONS AND INTERFACES 3 2 1 Connections and interfaces version Ethernet 4 2 2 Connections and interfaces version HV PLC 5 2 3 Connections and interfaces version NV PLC 6 3 GETTING STARTED 7 4 MOUNTING 7 ...

Page 3: ...ncluding connector plug only for NV PLC version 2 Connections and Interfaces All connections and interfaces are located on the rear mounted board of the device Depending on the version ordered various options are available for supplying the flush mounted unit with power Power supply PoE alternatively 6 56V 110 230 V 48V bell wire Connections and Interfaces Relay Trigger input 1 Trigger input 2 5V ...

Page 4: ...e power can alternatively be supplied via a plug in power supply 6 56 V A relay e g for switching a door opener and two trigger inputs are available In addition the device has a Wiegand output which is intended for connection to door controllers or similar CAT5e cable connection to PoE port CAT5e cable connection to Ethernet port PoE ports Ethernet ports INPUT GND IN2 IN1 RELAY NO NC COM ALTERNATI...

Page 5: ...twork is established via the supplied powerline adapter A relay e g for switching a door opener and two trigger inputs are available In addition the device has a Wiegand output which is intended for connection to door controllers or similar CAT5e cable connection to Ethernet port CAT5e cable connection Ethernet Port Power cable 230V AC connection to power socket Ethernet ports 5V Dat0 Dat1 GND 100...

Page 6: ...he supplied converter box which must be connected to a PoE port A relay e g for switching a door opener and two trigger inputs are available In addition the device has a Wiegand output which is intended for connection to door controllers or similar PoE ports Ethernet ports CAT5e cable connection to PoE Port CAT5e cable connection to Ethernet port Bell wire 48 56V DC connection to 2Wire converter I...

Page 7: ...admin Password 1234 Opening the enrollment area of the UP terminals Enrollment area for face recognition Enrollment card green FaceUP only Enrollment area for RFID cards Enrollment card red Further information about operation and configuration of the UP series can be found in the instructions on our homepage www adatis com for download 4 Mounting The UP series is designed for installation in 55 mm...

Page 8: ... entry must be provided After fixing the flush mount box the UP module is screwed to the flush mount box without frame this must be removed beforehand Corresponding holes are provided in the printed circuit board for this purpose Finally the glass frame is reattached to the module Schritt 1 Schritt 2 Schritt 3 Schritt 4 step 3 step 2 step 1 step 4 ...

Reviews: