953.050UK User Manual 

Connections 

1.

 

Local 24Vdc power input 

2.

 

Local audio input (mono, line level) 

3.

 

RJ45 socket 

 

Plug in the 8P8C connector from the 8-core control cable into the RJ45 
socket on the rear of the housing (3). 

 
If local 24Vdc power is being used

 

Connect the + wire to the 

DC24V POWER

 terminal Connect the - wire 

to the 

GND

 terminal (1) 

 
If a local audio signal is being connected

 

Connect the + wire to the 

AUDIO INPUT

 terminal Connect the - wire 

to the 

GND

 terminal (1) 

 

Operation 

 
To operate the TR86, touch or tap buttons as detailed below. 

 

4.

 

CH 

 and 

 step through audio sources (Line 1-4) for the zone 

5.

 

BUSY indicator is lit during paging or emergency alerts 

6.

 

+ and - increase or decrease output volume in steps 

7.

 

Audio source indicators light to show which source is selected 

8.

 

LOCAL 

 touch to switch to local audio input (if connected) 

9.

 

MUTE 

 touch to mute or un-mute all output for the zone.  

 

Backlights for LOCAL and MUTE buttons will be lit when active. 

 

 

Specifications 
 

Power supply 

24Vdc (from RZ45 or external power adaptor) 

Connection 

8P8C (RJ45) 

Terminals 

Local +24V, Ground, Local line input 

Controls 

Sources 1-4 (USB), Local, Mute, Level +/- 

Mounting depth 

38mm 

Dimensions 

86 x 86 x 38mm 

Weight 

128g 

 
 

 

 

Disposal:

 

The “Crossed Wheelie Bin” symbol on the product means that the product is classed as Electrical or 

 

Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life.  

The goods must be disposed of according to your local council guidelines. 

 

 

Errors and omissions excepted. 

 

Copyright© 2017. AVSL Group Ltd. 