HEALTH AND SAFETY INFORMATION
Control of substances hazardous to user health
For the type of material and where used in Dunatech boiler refer to the following chart
1. PAINTS:
General purpose black undercoat
NOT APPLICABLE
High temperature black coating
Sections
Boiler body bottom plate
Powder coating
All jackets
2. INSULATION AND SEALS
Rock-wool insulation board
NOT APPLICABLE
Glass-wool insulation board
Sections
(aluminum backed)
Smokehood
Fibre-glass rope and tape
Front door
Between bottom plate and
sections
Ceramic-fibre board
Front door
CFC free polyurethane spray/foam
NOT APPLICABLE
Refractory brick
NOT APPLICABLE
Asbestos products
NOT APPLICABLE
3. SEALANTS
Red-lead dye
Nipples
Ceramic/mineral compound gasket
Flanged stub pipes
(Isoplan/Frenzelit)
Water jointing flax
Tappings on sections
Grey paste jointing compound
Inter section joints
(Unipak A/S)
18
(U pa
S)
Fire cement
NOT APPLICABLE
Gas jointing compound
NOT APPLICABLE
Specific data sheets are available on request from ADARAD for those materials but the following material handling
and first aid procedures should in all cases be observed.
Paints, sealants, grey paste compound, ceramic-fibre boards
1. These materials contain organic solvents and should be used in a well ventillated area away from naked flames.
2. Do not allow to come into contact with the skin, eyes, inhale or swallow.
3. Use barrier cream or gloves to protect the skin, and goggles to protect the eyes from accidental contact.
4. Small quantities can be removed from clothes or skin with a proprietary paint remover or hand cleaning prdouct.
5. If inhaled, remove sufferer into fresh air, if swallowed clean mouth with and drink fresh water but do not induce
vomitting.
6. If in the eye, irrigate the eye with clean water and seek medical attention.
Sharp edges
Care should be taken when handling sheet metal panels that do not have safety or folded edges
Lifting cast iron sections
Care should be taken when lifting cast iron sections as they can weigth up to a few hundred kilograms and ADARAD
can confirm the weight of each individual section if required
Building and servicing the boiler/sections
When building the boiler, the section should always be built on a level base capable of supporting the full weight of
the boiler and the sections should always be supported on blocks of wood or props when positioning before final
bolting up. An unsupported section should never be left unattended.
Thermal insulation
1. Avoid contact with skin, eyes or inhaling dust.
2. If cutting insulation then do so in a well ventillated area using gloves to protect the hands, goggles to protect the
eyes, and a disposable dust mask
eyes, and a disposable dust mask
3. If a skin reaction or eye irritation is experienced then discontinue working with the material and seek medical advice.
Summary of Contents for DUNATECH 2012