2
Related documentation
Technical specifications
Title
Part #
Description
Network Configurations
97Ø8-8Ø46
Detailed information on how to network ALPHA signs.
ALPHA Remote Control Programming Manual
97Ø4-ØØØ2
Examples of how to program messages into ALPHA signs using a handheld
infrared remote control.
ALPHA Messaging Software User Manual v1.Ø
97Ø1-Ø2Ø2
Instructions on using the ALPHA Messaging software to program messages
into ALPHA signs.
All Modules
Dimensions:
2.75"W x 4.25"H x 1"D
Weight:
4 oz per module
Operating temperature:
60°C
Humidity range:
10 – 95% non-condensing
Mounting:
DIN rail 35 x 7 mm
Power Module
AC input voltage
1
Max. AC voltage: 25 Vrms
Min. AC voltage: 14 Vrms
Power consumption:
15W @ 24 Vrms
DC input voltage
Max. DC voltage: 36 VDC
Min. DC voltage: 18 VDC
Output voltage 24 VDC
Max. voltage: 36 VDC
Min. voltage: 18 VDC
Max. current: 700 mA
Bus output voltage 5 VDC
Max. voltage: 5.05 V
Min. voltage: 4.95 V
Max. current: 500 mA
Protection
Type: Polyswitch
Self-resetting: Yes
Terminals
Type: Screw
Wire size: 0, 14-2, 5
2
/ AWG 26 - 14
CPU Module
Operating voltage: 5 V
Current draw: 150 mA
Power consumption: 0.75 W
Communications
Serial (in):
Communication type: RS232
Terminal type: RJ11
Protocol: EZ95