AlphaEclipse StreetSmart Multiple Master Sign Connection (pn 1179630201)

March 28, 2006

Run the two communication cables through one of the conduit openings 

under

 the controller board:

Repeat steps #2 through #5, until all the signs are connected as shown below:

Complete the sign installation.

• See the “AlphaEclipse StreetSmart Sign Installation Manual” (pn 1179600101).

• Remember to earth ground the sign using the ground lug on the back of the sign.

Connect 
communication 
cables to these 
(see step #6.)

Power wire conduit hole

Communication conduit hole

Run communication 
cables through this 
conduit hole.

Do NOT run 
communication cables 
in the same conduit as 
the power wires.

COM 0

COM 2

MASTER UNIT

SERIAL ADDRESS = 1

SECONDARY MASTER UNIT

SERIAL ADDRESS = 2

To COM 0 in next sign.

Cont

r

ol cube

(bottom rightmost cube)

Cont

r

ol cube

(bottom rightmost cube)

5

Cont

r

olle

r

 boa

r

d

(bottom)

1

2 3 4

5

1 2 3 4

1 2 3 4 5 6 7

COM 0

5

Cont

r

olle

r

 boa

r

d

(bottom)

1

2 3 4

5

1 2 3 4

1 2 3 4 5 6 7

COM 0

SHIELD
BLACK
RED

SHIELD
BLACK
RED

SHIELD
BLACK
RED

SECONDARY MASTER UNIT

SERIAL ADDRESS = 3

Communication Cable Conduit:

• Run the two communication cables
  through a conduit.
• Do NOT run communication cables in the

same conduit as the power wires. 

• Cable that is 

not

run through a conduit 

  will deteriorate from exposure to sunlight.

CONNECT TO

COM 0 (MAIN RS485)

IN ADDRESS 3

CONNECT TO

COM 0 (MAIN RS485)

IN ADDRESS 2

To COM 2 in next sign.

SHIELD
BLACK
RED

SHIELD
BLACK
RED

CONNECT TO

COM 2 (TEMP PROBE)

IN ADDRESS 3

1

23

4

5

67

COM 2

1

23

4

56

7

COM 2

SHIELD
BLACK
RED

BLACK
RED

SHIELD

GREEN
WHITE

Tempe

r

atu

r

e p

r

obe (optional)

Mount the probe to a light-colored surface at least 6 feet
above ground and 

not

in direct sunlight.

CONNECT TO

COM 2 (TEMP PROBE)

IN ADDRESS 2

Ground lug