5-26
DuraStor 412R/6320SS/7320SS Installation and User’s Guide
9
Remove the I/O cards. See
Remove the defective storage subsystem from the rack cabinet.
Reverse the installation procedures in
Installing the New Storage Subsystem
1
Install the replacement storage subsystem in the rack cabinet.
See
.
2
Reinstall the I/O cards. Refer to the notes you made of the jumper
and switch settings to ensure they remain in the same positions.
3
Reinstall the power supplies. See
.
4
Reinstall the cooling fan module. See
.
5
Install the disk drives. See
for installation instructions.
6
If applicable, reinstall the RAID controllers in the same
positions as in the old storage subsystem. Refer to the notes you
made of the proper installation locations. (See
for installation instructions.)
Warning:
The connector is sensitive to alignment. Carefully
seat each controller’s connector and secure the controller
by closing the latches.
7
Reconnect the data cables and power cords. Refer to the notes
you made of the proper connection locations.
8
Replace the front bezel. See
9
Power
ON
DuraStor. Then, power
ON
the host computer. See
.
10
Verify that all systems are operating normally.
11
Use Storage Manager Pro or Disk Array Administrator to verify
that the replacement RAID controller has the correct firmware.
Note:
Active-active and active-passive dual controllers
require the same version firmware on both controllers and
the same amount of memory.
DuraStor IUG - Online.book Page 26 Friday, July 19, 2002 3:06 PM