![Adamson Systems Engineering 971-0005 User Manual Download Page 8](http://html1.mh-extra.com/html/adamson-systems-engineering/971-0005/971-0005_user-manual_2846329008.webp)
User Manual
S E R I E S
8
Power
When wiring an AC cable for use with this product in
a single-line system, use the wiring scheme described
below in Table 2 and illustrated with Fig. 1. All work
must be completed by a qualified technician.
Fig. 1
Hot or Live (L)
Brown
Neutral (N)
Blue
Protective Earth /
Ground (E or PE)
Green and Yellow
Table 2
powerCON True1 AC Cable Input Connector
powerCON True1 AC Cable Output Connector
The
CS Power Distribution Sysytem
(PDS, 914-0002 - 110 V/914-0003 - 230 V)
provides six individually
protected AC circuits of 208/230 V, 16 A.
When using the Adamson PDS, you can link a maximum of six CS7
loudspeakers per circuit.
Brown
Blue
Green and Yellow
100 V
115V
120 V
208 V
230 V
240 V
RMS Long-Term
3.45 A
3.00 A
2.88 A
1.66 A
1.50 A
1.44 A
RMS Idle
1.04 A
0.90 A
0.86 A
0.50 A
0.45 A
0.43 A
Peak
20.70 A
18.00 A
17.25 A
9.95 A
9.00 A
8.63 A
Table 1 - Single cabinet current draw