Fitting Instructions for Ritekey 30-01. Rev 3 June 2005.
1
Installing Keypad and Backplate
Fig.1 Positioning of Fixing Holes and Cable Outlet
Remove the back plate, which is fitted to rear of
the keypad, using a 2mm Allen key provided and
put the screw in a safe place.
Fig.2 Preparation and Installation of Back Plate
1. Select a suitable location to fit the keypad and mark
the position to two fixing screws and the cable
access hole as per fig.1
2. If fitting to brickwork use the rawl plugs provided
and drill two 6mm diameter holes to suit.
Otherwise, drill the two fixing holes 3mm in
diameter to allow a 4mm button head screw to cut
its own thread.
3. Install the cable run to the power supply and
the lock.
4. Ensure the diameter of the cable is sufficient for the
length of the run and the amperage draw of the lock
so as to minimise line drop. Alarm cable or bell
wire is not recommended for access control
installations.
5. Ensure the MOV supplied is fitted to the lock either
to its supply cables or on its supply connections on
its terminal block.