1. Measuring system: Turbine
2. Inlet/Outlet : 1” BSP/G female
3. Measuring range: 5 - 150 lpm
4. Accuracy ± 0.5%
5. Repeatability (typical): ± 0.3%
6. Max Pressure of use: 3,5 bar (50 psi)
7. Temperature of use: -10°C + 60°C
8. Display: 6 digits LCD
9. Power supply: Alkaline batteries 2x1.5V AAA
10. Impermeability rating: IP65
11.Weight: 0.25Kg
4.4 D��G�������
�R�B���
The meter is not
reading
The display is
not switching on
Inaccurate preci-
sion reading
�����B�� ���U��
1. turbine is blocked
2. wrong installation
3. Reed switches are
broken
4. turbine has been
reassembled reverse
1. exhausted batteries
2. bad contact on
batteries
1. flow rate too low or
too high
2.wrong calibration
3.air inside system
4. dirty magnets
���U�����
1. Disassemble &
clean turbine
2.verify thanks
to the arrow on
the meter that it
i correctly fitted
on the line.
3. contact your
supplier to get an
Exchange board
4. rotate the
turbine by 180°
1. change
batteries
2. verify batteries
positioning
1. verify technical
data on pump
flow rate
2.calibrate
3. verify that
pump is not
sucking air
4. clean magnets
4.3 �����K
If the meter has to be positioned in stock for a
while, clean it carefully. This will help to prevent
eventual damages.
11
ADAM PUMPS
• DI - FLOW IN LINE
5 .����H������ D��� D�-F��W
12V �U���R ��D��
1. Measuring system: Turbine
2. Inlet/Outlet : 1” BSP/G female
3. Measuring range: 5 - 150 lpm
4. Accuracy ± 0.5%
5. Repeatability (typical): ± 0.3%
6. Max Pressure of use: 3,5 bar (50 psi)
7. Temperature of use: -10°C + 60°C
8. Display: 6 digits LCD
9. Connection cable antiflame: 2m
10. Power supply: 12vDC - 10mAh (12,
brown 0v)
11. Relay contacts: max.voltage 24vdc 500mAh
(white,grey)
12. Pulser output: 0-12vDC, 100 imp/unit (green)
13. Impermeability rating: IP65
14. Weight: 0.25Kg