background image

 ©Adam Equipment Company 2019

 

 

Adam Equipment 

 

 

GK-Mplus INDICATOR 

 
 

Software revision: GK‐Mplus V1.02  

 

 

 

 

Summary of Contents for GK-Mplus

Page 1: ...Adam Equipment Company 2019 Adam Equipment GK Mplus INDICATOR Software revision GK Mplus V1 02...

Page 2: ...Equipment Company 2019 Easy Reference Model name of the indicator Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and...

Page 3: ...NTING OR WEIGHING 16 10 6 LIMITS STORING AND RECALLING 17 10 7 PERCENT WEIGHING 18 10 8 ANIMAL DYNAMIC WEIGHING 20 10 8 1 ANIMAL WEIGHING PROCEDURE 21 10 9 ACCUMULATED TOTAL 21 10 9 1 MANUAL ACCUMULAT...

Page 4: ...C COUNTS 41 15 2 8 F8 ZERO MODE 42 15 2 9 F9 FILTER SETTINGS 42 15 2 10 F10 CALIBRATION COUNT 42 15 2 11 F11 SELECT APPROVALS STANDARD 43 15 2 12 F12 DEFAULT PARAMETERS TO FACTORY VALUES 43 16 0 REPLA...

Page 5: ...with an audible alarm for check weighing The GK Mplus is supplied with a RS 232 bi directional interface and real time clock RTC The GK Mplus has a sealed keypad with colour coded buttons and a large...

Page 6: ...2 Seconds typical Operating Temperature 10 C 40 C 14 F 104 F Power supply 110V 240 VAC 50 60 Hz Battery Internal rechargeable battery Calibration Manual External Display 6 digits LCD digital displays...

Page 7: ...acy Avoid extremes of temperature Do not place in direct sunlight or near air conditioning vents Avoid unsuitable tables The table or floor must be rigid and not vibrate Avoid unstable power sources D...

Page 8: ...as a connector configured for a 6 wire load cell Connect the load cell platform to the indicator as shown below The cable length should be as short as possible using a large size wire to minimise erro...

Page 9: ...tion to the sense at the connector 5 0 KEYPAD AND DISPLAY 5 1 DISPLAY KEYS PRIMARY FUNCTION SECONDARY FUNCTION Zero Sets the zero point for all subsequent weighing The display shows zero Escape from a...

Page 10: ...select percent weighing RS 232 parameters Operation of the bar graph RTC settings User ID and Scale ID None Cnt Enter Parts Counting None Print It is used to print the results to a PC or printer usin...

Page 11: ...units Capacity Tracker A bar graph indicating the proportion of the scale capacity being used by the weight on the pan Battery Status The scale is in Percent weighing mode pcs The scale is in Parts co...

Page 12: ...nt and probably a different number i e 234 The counters cannot be reset to 0 they will increment until the display can no longer hold the values 1 to 999999 It is expected we will never have more than...

Page 13: ...ly charge the battery from empty When the battery is charged to full capacity the battery symbol will stop scrolling and it will show as fully charged 8 0 BACKLIGHT The backlight for the LCD can be se...

Page 14: ...ro the indicator if small amount of weight is still shown when the platform is empty 10 2 TARING 10 2 1 Manual tare Zero the indicator by pressing Zero The zero indicator will be on Place a container...

Page 15: ...ro to remove the tare value and display zero The Net indicator will disappear 10 3 WEIGHING To determine the weight of a sample first tare an empty container if used then place the sample in the conta...

Page 16: ...o measure accurately the count may become inaccurate It is suggested that the samples to be weighed should each weigh more than the resolution of the indicator After the sample has been weighed the in...

Page 17: ...d 10 5 CHECK WEIGHING Check weighing is a procedure to display a visual indication or sound an alarm when the weight on the platform meets or exceeds the values stored in the memory The memory holds v...

Page 18: ...s Tare to accept the value If you want to reset the value to zero press CE to clear the value The limits are displayed in the weighing unit in use To set the high limit press High Limit the display wi...

Page 19: ...e beeper During Check weighing the current limits can be stored or previously stored units can be recalled Press the Lim key If you are already in the check weighing mode the display will ask if you w...

Page 20: ...for a new sample to be counted 2 If the recalled unit is a percent weighing limit the display will show the last sample value used ready for a new sample to be weighed 3 If the memory location was emp...

Page 21: ...imal points will depend on the weight used A smaller weight will show only 100 while a larger weight might show 100 00 If the indicator was showing zero weight before entering this function then the u...

Page 22: ...to advance to the second function P2 Ani Animal weighing Press Tare to enter the animal weighing function To use the Animal Weighing function it is necessary to set the amount of filtering required f...

Page 23: ...flash Ani twice and be ready for the next animal To weigh a second animal press the Tare key if necessary to zero the display and place the next animal on the platform It is also possible to simply p...

Page 24: ...mal The weight can be output to a printer or PC using the RS 232 interface When the indicator is at zero place a second weight on the platform When stable press Print to accumulate the weight The disp...

Page 25: ...y is stable indicating the value is accepted Remove the weight The display will show ACC 1 and then the total in the memory before it returns to zero Adding a 2nd weight will repeat the process While...

Page 26: ...eight with the selected weighing unit through the RS 232 interface Default Specifications Connector The indicator can be set to print text in English French German Spanish Italian or Portuguese See th...

Page 27: ...parts are printed cr lf cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf User ID 234567 cr lf cr lf Net Wt 1 234 kg cr lf Net Wt or Gross Wt Unit Wt 123 g cr lf g for metric...

Page 28: ...r lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf User ID 234567 cr lf cr lf cr lf TOTAL No 5 cr lf Wt 1 234 kg cr lf PCS 10 pcs cr lf cr lf cr lf cr lf Net 1 234 kg cr lf Net...

Page 29: ...ortuguese Net weight Net Wt Pds Net Net Gew Pso Net Pso Netto Pso Liq Weight per unit counted Unit Wt Pds unit Gew Einh Pso Unid Pso Unit Pso Unid Number of items counted Pcs Pcs Stck Piezas Pezzi Pec...

Page 30: ...each command T cr lf Tares the indicator to display the net weight This is the same as pressing Tare Z cr lf Sets the zero point for all subsequent weighing The display shows zero P cr lf Prints the r...

Page 31: ...using the numeric keypad For the calibration it is best to use a weight close to the full capacity of the indicator If the mass is different from the displayed value enter the value of the mass in who...

Page 32: ...or press the Func key to advance through the groups FUnC 1 FUnC 2 FUnC 3 and FUnC 4 Press Tare to enter the desired group of parameters Press Zero to return to the group FUnC 1 If you press Zero again...

Page 33: ...any time With LLK set to Preset PSt the user is allowed to use one of the preset limits only oFF F2 bEP This parameter sets the Beeper for the Keypad Kp and for the Check weighing Ck If Ck is set to o...

Page 34: ...s Func to view the options for the parameter settings Press Tare to confirm the change and then advance to the next parameter by pressing the Func key Press Zero to return to the group FUnC 2 If you p...

Page 35: ...sh FrEnCH French SPAn Spanish GErmAn German iTALi Italian PortuG Portuguese EnGLi C6 UId Set User ID To be entered manually 000000 C7 Sid Set Scale ID To be entered manually 000000 C8 LAb Label report...

Page 36: ...rameters are used to control the operation of the indicator Parameter Description Options Default setting S1 Un Enable or disable weighing units Only USA scales have imperial unit kg g kg S2 bL Backli...

Page 37: ...for decimal places as dot or comma dot S9 AZ Auto Zero settings oFF 0 25 0 5 0 5 S10 rE Battery recharging status Shows the battery charging voltage and current 13 4 PERCENT WEIGHING AND ANIMAL WEIGH...

Page 38: ...Err 5 Press button to zero and zero when power on Scale already zeroed with no mass on weighing pan Err 6 Can t Tare for negative weight Weight on weighing pan below zero Err 7 Can t wait until stable...

Page 39: ...d below Or if the Calibration and Parameters have been enabled see 15 2 10 the user must enter the correct password to have access See Section 6 0 Entering passcode 0000 will allow calibration as show...

Page 40: ...press the Tare key during the time the calibration counters are being displayed Enter the number 2006 when P is displayed and then press Tare The displays will show the first parameters called F1 CAL...

Page 41: ...nd mass If the indicator has been calibrated once the values will be stored If this is the first time the indictor is calibrated the user must enter the values for the calibration masses It is necessa...

Page 42: ...APACITY To enter this parameter press the Tare key when F3 CAP is shown The display will show the current capacity Enter the numeric values using the keypad The indicator will check the number of divi...

Page 43: ...value Press Zero to return to weighing 15 2 6 F6 SUCCESSIVE TARE To enter this parameter press the Tare key when F6 SCS is shown The display will show if the successive tare is on or oFF Press the Fu...

Page 44: ...enter this parameter press the Tare key when F9 FL is shown The display will show the current filter setting which can be SLoWES SLoWEr FAStEr or FAStES Press the Func key to change the value Press T...

Page 45: ...hen F11 AP is shown The display will show the current setting nonE oiML SA AuS or ntEP Press the Func key to change the value Press Tare to accept the displayed value Press Zero to return to weighing...

Page 46: ...PARTS AND ACCESSORIES If you need to order any spare parts and accessories contact your supplier or Adam Equipment A partial list of such items is as follows Main Power cord or adaptor for USA versio...

Page 47: ...hods B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep a pr...

Page 48: ...equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equi...

Page 49: ...Con Continuous C4 Aon Enable Accumulation on oFF C5 Ln Language for printing EnGLiS English FrEnCH French SPAn Spanish GErMAn German itALi Italian PortuG Portuguese C6 Uid User ID Enter using numeric...

Page 50: ...Adam Equipment Company 2019...

Page 51: ...al environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio comm...

Page 52: ...ne 49 0 4340 40300 0 Fax 49 0 4340 40300 20 e mail vertrieb aeadam de Adam Equipment S A Pty Ltd 7 Megawatt Road Spartan EXT 22 Kempton Park Johannesburg Republic of South Africa Phone 27 0 11 974 974...

Reviews: