background image

 

© Adam Equipment Company 2009 

 

1.0  INTRODUCTION 

 

  The 

CBC 

series  provides  accurate,  fast  and  versatile  counting 

scales.  

 

  There are 2 type of scales within the 

CBC

 series-   

 

CBC

 scales are gram/ kilogram only scales and the 

CBCa 

scales 

are  changeable  from  pounds  to  kilograms.  The  scales  have  the 
same functions except that 

CBCa 

scales have the ability to toggle 

between the two weighing units. 

 

  There  are  5  models  in  each  type  with  capacities  up  to  48  kg  / 

100lb.  

 

  The  scales  have  stainless  steel  weighing  platforms  on  an  ABS 

base assembly. 

 

  All scales are supplied with a RS-232 bi-directional interface and 

real time clock (RTC). 

 

  The  scales  have  sealed  keypad  with  colour  coded  membrane 

switches  and  there  are  3  large,  easy  to  read  liquid  crystal  type 
displays (LCD). The LCD’s are supplied with a backlight. 

 

 

The scales include automatic zero tracking, audible alarm for pre-
set  counts,  automatic  tare,  pre-set  tare,  an  accumulation  facility 
that allows the count to be stored and recalled as an accumulated 
total.

 

 

Summary of Contents for CBC SERIES

Page 1: ...Adam Equipment Company 2009 Adam Equipment CBC SERIES P N 8680 Revision C4 February 2009 Software rev 3 06 above...

Page 2: ...Adam Equipment Company 2009...

Page 3: ...ARTS COUNTING 10 6 3 1 Setting Unit Weight 10 6 3 2 Counting more parts 11 6 3 3 Automatic part weight updates 11 6 3 4 Check counting 12 6 3 5 Manually Accumulated Totals 12 6 3 6 Automatic Accumulat...

Page 4: ...Adam Equipment Company 2009 2...

Page 5: ...5 models in each type with capacities up to 48 kg 100lb The scales have stainless steel weighing platforms on an ABS base assembly All scales are supplied with a RS 232 bi directional interface and re...

Page 6: ...CBC 16a UNITS OF MEASURE MAXIMUM CAPACITY TARE RANGE READABILITY REPEATIBILITY LINEARITY Kilograms 8 0000 kg 8 kg 0 0002 kg 0 0002 kg 0 0004 kg Pounds 16 0000 lb 9 9995 E E lb 0 0005 lb 0 0005 lb 0 00...

Page 7: ...nce Housing ABS Plastic Stainless Steel platform Pan Size 225 x 275mm 8 9 x 10 8 Overall Dimensions wxdxh 315 x 355 x 110mm 12 4 x 14 x 4 3 Net Weight 4 1 kg 9 lb Applications Counting Scales Function...

Page 8: ...water Do not spray or immerse the scales in water Avoid air movement such as from fans or opening doors Do not place near open windows or air conditioning vents Keep the scales clean Do not stack mat...

Page 9: ...the displayed values when Auto print is switched off MR To recall the accumulated memory Pst To set the upper limit for the number of items counted When this upper limit is exceeded the scale will sou...

Page 10: ...2 UNIT WEIGHT DISPLAY This display will show the unit weight of a sample This value is either input by the user or computed by the scale The unit of measurement is grams on CBC and pounds on CBCa sca...

Page 11: ...1 ZEROING THE DISPLAY You can press the Zero key at any time to set the zero point from which all other weighing and counting is measured This will usually be necessary only when the platform is empt...

Page 12: ...inputting a known unit weight using the keypad A Weighing a sample to determine the Unit Weight To determine the average weight of the items to be counted you will need to place a known quantity of th...

Page 13: ...cale can be tared to account for the container weight as discussed in the earlier section After the scale is tared the items to be counted are added and the Count display will show the number of items...

Page 14: ...nd count shown on the display can be added to the values in the memory by pressing the M key The Weight display will show the total weight the Count display will show the total accumulated count and t...

Page 15: ...applications You need to enter a secure menu by entering a password when requested Press Tare once during the initial counting of the display after the power is turned on The Weight display will show...

Page 16: ...ill return to the menu Record the new password in a secured place To exit a parameter press the Zero key 8 0 CALIBRATION The CBC scales are calibrated using metric weights and CBCa scales are calibrat...

Page 17: ...displayed then repeat the process Suggested Calibration weights for CBC Series CBC 4 CBC 8a CBC 8 CBC 16a CBC 16 CBC 35a CBC 32 CBC 70a CBC 48 CBC 100a 2 kg 5 Ib 4 kg 10 lb 10 kg 30 lb 20 kg 50 lb 30...

Page 18: ...hat is current RS 232 output of weighing data ASCII code Adjustable Baud rate 600 1200 2400 4800 9600 and 19200 baud 8 data bits No Parity 9 pin D subminiature socket Pin 3 Output Pin 2 Input Pin 5 Si...

Page 19: ...mands must be sent in upper case letters i e T not t Press the Enter key of the PC after each command T cr lf Tares the scale to display the net weight This is the same as pressing Tare key Z cr If Se...

Page 20: ...s will guide you through the parameter selected and the options available The parameters and their functions are Displays Weight Unit Weight Count Options Functions Port on On oFF Enable or disable th...

Page 21: ...cumulate automatically when stable Print key no function Print continuously and accumulate when M is pressed Print key no function Print continuously M and Print key have no function 9 3 REAL TIME CLO...

Page 22: ...te Err 2 is not the permissible values For example 34th day of a month is an invalid entry 9 4 AUTO SLEEP FUNCTION This function may be enabled or disabled by the user If enabled when the scale is not...

Page 23: ...s for full capacity Just under the Count display is an LED to indicate the status of battery charging When the scale is plugged into the mains power the internal battery will be charged If the LED is...

Page 24: ...at the step that caused the message turning the balance on carry out the calibration or other functions If the error message is still shown contact your dealer for further support ERROR CODE DESCRIPTI...

Page 25: ...uld be kept ready A Details of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods B Details of the unit purchased This part of information should...

Page 26: ...equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equi...

Page 27: ...n a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with t...

Page 28: ...ted in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment w...

Reviews: