background image

© Adam Equipment Company 2000 

1.4   KEYBOARD FUNCTION 

 

The keys have a primary function as identified within the key. The keys are also used 

when setting the parameters to select options and these secondary functions are 

labelled under the keys. 

 

 

KEY 

 

Primary Function 

 

 

Secondary Function 

 

ON/OFF 

 

 

Turn display on or off 

 

 

MODE 

 

Select weighing, counting 

or percentage weighing 

mode 

 

 

Select Parameter Set-up 

Mode 

 

UNITS / unit 

 

Select weighing units 

 

Select weighing units to 

set as initial unit or enable. 

 

 

PCS / next 

 

Set initial sample size 

during parts counting or 

percent weighing. 

 

 

Select next option during 

parameter set-up. 

 

TARE 

 

Set display to zero to tare 

the weight of a container. 

 

 

 

ZERO 

 

Set the initial zero on the 

display. 

 

 

 

LIGHT / increment 

 

Turn the backlight on or 

off. 

 

 

Increment parameter 

values during set-up. 

 

ENTER / select 

 

Confirmation key. 

Print key. 

 

 

Confirm setting during set-

up. 

 

Summary of Contents for ACB-1200H

Page 1: ...Adam Equipment Company 2002 Adam Equipment ACB SERIES ADAM EQUIPMENT CO LTD pn 3426 rev H November 02...

Page 2: ...to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment The equipment generates uses and can radiate radio frequency energy and if not...

Page 3: ...CAL Auto Calibration Customised weight 10 8 2 InitU To choose the initial unit while turning on 10 8 3 Unit To choose the weighing units to enable 11 8 4 A OFF To choose the time of AUTO OFF 11 8 5 tr...

Page 4: ...Adam Equipment Company 2000 1...

Page 5: ...ud 1 1 INSTALLING THE BALANCE Unpack the balance carefully Place the scale on a stable surface The weighing area should be kept clean and dry Do not install the balance near extremes of heat and cold...

Page 6: ...The 4 sides slide together to make a box then the top can be placed over the top for additional protection The breeze shield fits on top of the scale positioned by the ridges on the cover 1 3 DISPLAY...

Page 7: ...ng counting or percentage weighing mode Select Parameter Set up Mode UNITS unit Select weighing units Select weighing units to set as initial unit or enable PCS next Set initial sample size during par...

Page 8: ...tracted by placing an empty container on the scale When the display is stable press the TARE key The display will become zero and the display will have a tare indication Cancel the tare function by pr...

Page 9: ...eighing with the MODE key press the UNITS key to choose either 100 0 100 00 b Put the item to be considered 100 onto the pan and press the PCS key During the sampling the symbol will be flashing and w...

Page 10: ...he display will show the Calibration Weight Value Put the same weight on the platform When the display is stable the scale will calibrate Verify the calibration by removing the mass and checking it ag...

Page 11: ...ed from the scale Do not use the power supply at the same time as batteries are installed Remove the batteries first Power supplies 1 9V 300mA AC DC adapter 2 4 pcs C size dry cell batteries Batteries...

Page 12: ...ted it will print once automatically when the scale becomes stable and if ser has been selected it will print continuously The data format is as follows 20 characters are sent with the following field...

Page 13: ...desired 3 The functions will change each time the PCS next key is pressed The functions are CAL InitU Unit A Off trn rAtE Filxx Zerox b2x Acy trACx CAL 8 1 CAL Auto Calibration Customised weight Selec...

Page 14: ...ct no to disable auto off Then press ENTER select to return to weighing or PCS next key to continue to another function mode 8 5 trn To choose RS 232 TRANSMISSION METHOD Press the ENTER select key to...

Page 15: ...to confirm and return to normal weighing or press the PCS key to continue to another function mode 8 9 b2 x To choose the Auto Zero recovery range Press the LIGHT increment key to choose the Auto Zero...

Page 16: ...to choose the range from 0 to 5 Then press the ENTER key to confirm and return to normal weighing or press the PCS key to continue to another function mode Note When the scale is in the function mode...

Page 17: ...0 0005 42 x 0 001 dr 84 x 0 005 160 x 0 01 330 x 0 02 840 x 0 05 1600 x 0 1 330 x 0 01 660 x 0 02 GN 2300 x 0 1 4600 x 0 2 9200 x 0 5 23000 x 1 46000 x 2 9200 x 0 2 18000 x 0 5 ozt 4 8 x 0 0002 9 6 x...

Page 18: ...POUND 453 59237 g 1 oz AVOIRDUPOIS OUNCE 28 349523 g 1 dr AVOIRDUPOIS DRAM 1 7718451 g 1 gn GRAIN UK 0 0647989 g 1 ozt TROY OUNCE 31 103476 g 1 dwt PENNYWEIGHT 1 555174 g 1 MM MOMME Japan 3 749996 g...

Page 19: ...Adam Equipment Company 2000 16 APPENDIX PARAMETER SETTING MENU...

Page 20: ...laboratory balances Basic range of top loading balances for schools and educational establishments Counting scales for general industrial and warehouse applications Digital weighing check weighing sca...

Reviews: