background image

ZHT 

100 (6 in 1)

9

Warranty

This product is warranted by the manufacturer to the original purchaser to be free from defects in material and workmanship under 

normal use for a period of two (2) years from the date of purchase.

During the warranty period, and upon proof of purchase, the product will be repaired or replaced (with the same or similar model at 

manufactures option), without charge for either parts of labour. 

In case of a defect please contact the dealer where you originally purchased this product. The warranty will not apply to this product 

if it has been misused, abused or altered. Withiut limiting the foregoing, leakage of the battery, bending or dropping the unit are 

presumed to be defects resulting from misuse or abuse.

Exceptions from responsibility 

The user of this product is expected to follow the instructions given in operators’ manual.

Although all instruments left our warehouse in perfect condition and adjustment the user is expected to carry out periodic checks of 

the product’s accuracy and general performance.

The manufacturer, or its representatives, assumes no responsibility of results of a faulty or intentional usage or misuse including any 

direct, indirect, consequential damage, and loss of profits.

The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of profits by any disaster 

(earthquake, storm, flood ...), fire, accident, or an act of a third party and/or a usage in other than usual conditions.

The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits due to a change of data, loss 

of data and interruption of business etc., caused by using the product or an unusable product.

The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused by usage other thsn 

explained in the users’ manual.

The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong movement or action due to connect-

ing with other products.

Summary of Contents for ZHT 100 (6 in 1)

Page 1: ...Operating manual Thermo Hygrometer Model ZHT 100 6 in 1 Manufacturer Address WWW ADAINSTRUMENTS COM...

Page 2: ...uction 3 2 Appearance 3 3 Illustration of display screen 4 4 Operation instructions 5 5 Trouble shootings 8 6 Technical data 8 7 Warranty Exceptions from responsibility 9 Appendix 1 Certificate of acc...

Page 3: ...ternal temperature probe INTRODUCTION ADAZHT 100 6 in 1 Thermo Hygrometer equipped with advanced sensor technology is used to measure environ mental parameters of storage and production warehouses It...

Page 4: ...Celsius F Fahrenheit G Probe tempeartureT2 Wet bulb temperature H Wet bulb indicator I Condensation temperature difference T2 DP J Probe temperature K Ambient temperature T1 Dew point DP L Dew point i...

Page 5: ...the LCD screen will display the difference switch ing between T1 Dew point DP Ambient temperature and T T1 T2 6 If the external probe is not plugged in press WBT button and it only shows WBT reading I...

Page 6: ...bottle in the market A Please press to deactivate auto power off function and turn the unit on press the upper left button then press the middle power button When the screen be full displayed release...

Page 7: ...ons and do not burn the batteries Strap insulated tape around the battery charges to avoid unsafe contacts with other objects Many countries have regulations about the batteries disposing Please follo...

Page 8: ...TA TROUBLE SHOOTINGS Problems Causes Solutions No display on the screen Battery runs down Check and replace the battery is indicated Low battery Replace the battery Backlight Auto off About 10s Auto P...

Page 9: ...perfect condition and adjustment the user is expected to carry out periodic checks of the product s accuracy and general performance The manufacturer or its representatives assumes no responsibility...

Page 10: ...oducts or parts caused by misuse including without limitation misapplication or nrgligence of the terms of service instruction 6 Power supply units chargers accessories wearing parts 7 Products damage...

Page 11: ...r is obligatory Technical examination of instruments for fault identification which is under the warranty is made only in the authorized service center In no event shall manufacturer be liable before...

Page 12: ...____________________ _____________ name and model of the instrument Corresponds to ______________________________________________________________ designation of standard and technical requirements Dat...

Page 13: ...ZHT 100 6 1 ADAINSTRUMENTS WWW ADAINSTRUMENTS COM...

Page 14: ...ZHT 100 6 in 1 14 1 15 1 15 2 16 3 17 4 20 5 20 6 21 1 2...

Page 15: ...ZHT 100 6 in 1 15 1 2 3 4 5 6 7 MAX MIN 8 9 10 MAX MIN 1 2 3 4 5 6 7 8 9 10...

Page 16: ...ZHT 100 6 in 1 16 A B C MAX D MIN E F G T2 H I T2 DP J K T1 DP L DP M T1 T2 N 2 P...

Page 17: ...ZHT 100 6 in 1 17 1 9 2 10 3 F C F 4 10 5 DEW 1 DP DEW DEW 1 2 T T1 T2 DP 1 6 WBT Wb WBT T2 DP Wb 2 7 MAX MIN MAX MIN MIN MAX 8 HOLD 9 10 3 20 11 HOLD ON OFF...

Page 18: ...ZHT 100 6 in 1 18 1 2 3 4 5 a b 30 6 1 2 1 33 40 40 33 3 2 75 40 40 75...

Page 19: ...ZHT 100 6 in 1 19 1 2 2...

Page 20: ...ZHT 100 6 in 1 20 T1 0 C 50 C T2 10 C 70 C 0 99 9 1 C 1 5 C 5 95 3 25 C 0 1 C 0 1 10 20 1 9 6F22 6LR61 0 C 40 C 5 95 RH 30 60 C 85 RH 192 61 31 107...

Page 21: ...ZHT 100 6 in 1 21 2...

Page 22: ...1 2 3 4 5 6 7 8 9 WWW ADAINSTRUMENTS COM info adainstruments com...

Page 23: ..._______________________________________________ ___________________ _________________ ___________________ 24 II 454 491 _________________________________...

Page 24: ...___________________________ _____________________________________________________________________________ _______________ ______________________________________________________________________________...

Page 25: ......

Page 26: ...ADA MEASUREMENT FOUNDATION WWW ADAINSTRUMENTS COM...

Reviews: