Press button (6) again to have only one additional vertical line. Press button (6) 

one more time to turn off additional vertical line and switch on horizontal line.

Use the receiver (supplied separately) mode to enlarge the working mode 

and for the operation in bright illumination.

TO CHECK THE ACCURACY

          TO CHECK THE ACCURACY OF LINE LASER (SLOPE OF PLANE)

Set up the line laser between two walls, the distance is 5m.Turn on the 

Line Laser and mark the point of cross laser line on the wall. Set up the 

line laser 0,5-0,7m away from the wall and make, as described above, the 

same masrks. If the difference {a1-b2} and {b1-b2} is less then the value 

of “accuracy” (see spesifications), there is no need in calibration. Example: 

when you check the accuracy of Line Laser the difference 3 is {a1-a2}=5 

mm and {b1-b2}=7 mm. The line laser’s error: {b1-b2}-{a1-a2}=7-5=2 mm. 

Now you can compare this error with standard error. If the accuracy of Line 

Laser isn’t corresponding with claimed accuracy, contact the authorized 

service center.

          TO CHECK THE ACCURACY OF HORIZONTAL BEAM

Choose a wall and set laser 5m away from the wall. Turn on the laser and 

cross laser line is marked A on the wall. Find another point M on the hori-

zontal line, the distance is around 2.5m. Swivel the laser, and another cross 

point of cross laser line is marked B. Please note the distance of B to A 

should be 5m. Measure the distance between M to cross laser lune, if the 

difference is over 3mm, the laser is out of calibration, please contact with 

seller to calibrate the laser.

TO CHECK PLUMB

Choose a wall and set laser 5m away from the wall. Mark point A on the 

wall, please note the distance from point A to ground should be 3m. Hang 

a plumb line from A point to ground and find a plumb point B on ground. 

Turn on the laser and make the vertical laser line meet the point B, along 

the vertical laser line on the wall and measure the distance 3m from point

B to another point C. Point C must be on the vertical laser line, it means 

the height of C point is 3m. Measure the distance from point A to point C, if 

the distance is over 2 mm, please, contact with seller to calibrate the laser.

English

3

4

Summary of Contents for CUBE 3D

Page 1: ...Line Laser OPERATING MANUAL CUBE 3D GREEN adainstruments com...

Page 2: ...2 English 1 2 3 4 5...

Page 3: ...imilar parts during construction and installation works SPECIFICATIONS FOR ARMO MINI Laser beam 2 vertical lines 1 horizontal line Light sources 2 laser diodes 515 nm Laser safety class Class 2 1mW Ac...

Page 4: ...oid moisture condensation Inside the Instrument dry out the case and laser line laser Check regularly line laser adjustment Keep the lens clean and dry To clean the line laser use a soft cotton napkin...

Page 5: ...ontact the authorized service center TO CHECK THE ACCURACY OF HORIZONTAL BEAM Choose a wall and set laser 5m away from the wall Turn on the laser and cross laser line is marked A on the wall Find anot...

Page 6: ...curacy Large fluctuation of temperature if instrument will be used in cold areas after it has been stored in warm areas or the other way round please wait some minutes before carrying out measurements...

Page 7: ...he user of this product is expected to follow the instructions given in op erators manual Although all instruments left our warehouse in perfect condition and adjustment the user is expected to carry...

Page 8: ...4 Service by anyone other than an authorized service center 5 Damage to products or parts caused by misuse including without lim itation misapplication or nrgligence of the terms of service instructio...

Page 9: ...ark of thr seller is obligatory Technical examination of instruments for fault identification which is under the warranty is made only in the authorized service center In no event shall manufacturer b...

Page 10: ...10 Russian 1 2 3 4 5...

Page 11: ...11 Russian 2 1 2 515 nm 2 1 2 10 3 70 40 3xAAA 1 5 1 4 10 45 240...

Page 12: ...12 Russian 1 2 3 4 1 4 5 6 3 A 3 3 On Off OFF 3 6 6 6 2 1...

Page 13: ...13 5 180 0 5 0 7 1 2 b1 b2 1 2 5 b1 b2 7 b1 b2 1 2 7 5 2 5 2 5 Russian 3 4...

Page 14: ...14 Russian 5 3 3 10 3...

Page 15: ...15 Russian 2 2 1 515 nm IEC 60825 1 2014 21 CFR 1040 10 1040 11 Laser Notice No 50 24 2007 7 5...

Page 16: ...16 Russian 2...

Page 17: ...17 Russian...

Page 18: ...18 Russian 1 2 3 4 5 6 7 8 9...

Page 19: ...19 Russian _______________________________________ ___________________ _______________________ ________________________________ 24 II 454 491 _________________________________...

Page 20: ...20 Portuguese 1 2 3 4 5...

Page 21: ...a o sem com receptor 70 40 m Baterias 3xAAA 1 5V Rosca de trip 2x1 4 Temperatura de funcionamento 10 C 45 C Peso 240 g LINHA DE LASER UNCIONES 1 Laser emitido pelo vidro 2 Tampa da bateria 3 Compensad...

Page 22: ...compensa o 3 para a posi o ON o instrumento desliga na posi o OFF Nessa posi o ON o p ndulo estar na posi o livre e ser travado na posi o OFF Ao girar uma linha horizontal e uma vertical ser projetad...

Page 23: ...de calibra o entre em contato com o vendedor para calibrar a laser PARA VERIFICAR PRUMO Escolha uma parede A uma distancia de 5m da parede ligue o nivel Marque um ponto na parede observe a dist ncia...

Page 24: ...s depois de ter sido armazenado em reas quentes ou o con tr rio por favor espere alguns minutos antes de realizar medi es ACEITABILIDADE ELETROMAGN TICA EMC N o pode ser completamente exclu do que est...

Page 25: ...so armaz m em perfeito estado e ajuste o usu rio esperado para realizar verifica es peri dicas de precis o do produto e desempenho geral O fabricante ou o seu representantes n o assume nenhuma respons...

Page 26: ...instru o de servi o sem acordo escrito provis rio do perito fornecedor 4 Servi o por qualquer pessoa que n o seja um centro de servi o autor izado 5 Danos aos produtos ou pe as causadas por mau uso in...

Page 27: ...igat ria Exame t cnico de instrumentos para identifica o de falhas que est sob a garantia feita apenas no centro de servi o autorizado Em nenhum caso o fabricante ser respons vel perante o cliente por...

Page 28: ...28 Spanish 1 2 3 4 5...

Page 29: ...i n l ser de 515 nm Clase de seguridad l ser Class 2 1mW Precisi n 2mm 10m Rango de auto nivelaci n 3 Rango de funcionamiento con sin receptor 70 40 m Fuente de alimentaci n 3xAAA 1 5V Rosca para tr p...

Page 30: ...l nea parpadeante y la se al sonora indican que el dis positivo no se ha instalado dentro del margen de compensaci n 3 Para trabajar correctamente alinee la unidad en un plano horizontal Gire el inte...

Page 31: ...da el l ser y el lugar donde se cruza el laser debe marcar la letra A Gire el instrumento para que el rayo laser cambie respecto al primer punto en 2 5m a la izquierda Encuentre otro punto M en la l n...

Page 32: ...os por ejemplo radiaci n electromagn tica intensiva cerca de instalaciones industriales o transmisores de radio L SER CLASE 2 LA ETIQUETA DE CUIDADO DEBE ESTAR EN INSTRUMENTO L SER CLASIFICACI N L SER...

Page 33: ...dor orig inal de estar libre de defectos en el material y la mano de obra Bajo uso normal por un per odo de dos 2 a os a partir de la fecha de compra Durante el per odo de garant a y con la prueba de...

Page 34: ...XTIENDE A LOS SIGUIENTES CASOS 1 Si el n mero de producto est ndar o serie se cambia se borra se elim ina o ser ilegible 2 Mantenimiento peri dico reparaci n o cambio de piezas como resulta do de su u...

Page 35: ...dor es obligatorio El examen t cnico de los instrumentos para la identificaci n de fallos que est bajo la garant a se realiza nicamente en el centro de servicio autorizado En ning n caso el fabricante...

Page 36: ...adainstruments com ADA International Group Ltd No 6 Building Hanjiang West Road 128 Changzhou New District Jiangsu China Made In China...

Reviews: