5.2.5
BER Test
Click BER Test will show picture as below, include BER Enable, Testing Port,
Start and Stop, Port Status (Frame synchronization or Frame Desynchronization), Bit
Error Rate and Error timing, as shown in Fig 5.1-5. If you need test Error for one
link, first you should click “enable” and “start”, and click “Submit”, Web Server will
show result. During Testing click “Refresh” will show result of now status.
Fig 5.2-5 BER Test
5.3
Alarm Management
This section includes E1 channels, Ethernet port and power alarm shielding.
5.3.1
Alarm Shielding Management
If set alarm mask, then this alarm will be shielded at alarm log, alarm indicator
on panel and will not display no matter what situation is unless the mask is canceled.
E1 channel supports not only shielding any alarm of any channel, but also batch
shielding. But Ethernet port alarm and power alarm shielding can only be set one by
one. As shown in Fig 5.3-1 and Fig 5.3-2.
Fig.5.3-1 E1 alarm management
Fig.5.3-2 Ethernet alarm management
5.4
Ethernet Management
This section includes Ethernet port management, Ethernet senior management