en
33
N 2 Condens :
664Y5000 • C
EN
FR
NL
ES
IT
DE
PL
RU
MAINTENANCE
Cleaning the trap
1. Loosen the trap ring.
2. Check that the condensate exhaust pipe is not blocked.
3. Clean the trap with soap and water.
4. Make sure to leave enough water in the trap before reassembly, or pour 20 cl of water
in the condenser before reassembly.
5. Insert the trap in the condenser outlet. Replace the O-ring if necessary.
6. Hold the trap in position by re-tightening the ring. Pull the trap downwards to check it
is secured.
7. Make sure to reinstall the condensate exhaust pipe so that there is a sufficient gradient
for the condensate drainage.
INSPECTION OF SAFETY DEVICES
Check that all thermostats and safety devices are working properly: boiler thermostat, safety
thermostat, safety valves, etc.
DRAINING OF THE BOILER
1. Switch the boiler off.
2. Connect a flexible pipe between the boiler drain valve and the drain outlet.
3. Open the automatic air vent and the drain valve.
4. Allow the water to flow to the drain.
COMMISSIONING AFTER MAINTENANCE
See chapter “Commissioning”