ACV 06627301 Installation Operation & Maintenance Download Page 3

SLE - SLE Plus: A1007847 - 661Y2100 • D

Table of Contents

STARTING UP ................................................................................................ 25
Safety instructions to fill the tank

.............................................................................................25

Filling

 ............................................................................................................................................................26

Checks before starting up

 ............................................................................................................28

Starting up

 ................................................................................................................................................28

MAINTENANCE ............................................................................................. 29
Periodic checks by the user

 ........................................................................................................29

Annual maintenance

 .........................................................................................................................29

Draining

......................................................................................................................................................30

Bringing back into service after maintenance

 .................................................................31

Troubleshooting

 ...................................................................................................................................32

3

EN

Summary of Contents for 06627301

Page 1: ...Smart E 130 160 210 240 300 Smart E Plus 210 240 300 Installation Operation Maintenance Instructions for the User and the Installer A1007847 661Y2100 D...

Page 2: ...g connections 10 Domestic hot water connections 10 Main characteristics 11 Domestic hot water performances 11 Electrical characteristics 12 INSTALLATION 13 Package contents 13 Tools required for the i...

Page 3: ...ING UP 25 Safety instructions to fill the tank 25 Filling 26 Checks before starting up 28 Starting up 28 MAINTENANCE 29 Periodic checks by the user 29 Annual maintenance 29 Draining 30 Bringing back i...

Page 4: ...only be replaced by genuine parts Our water heaters are designed and manufactured for the exclusive purpose of heating and storing domestic hot water The domestic hot water heaters must only be heate...

Page 5: ...SLE SLE Plus A1007847 661Y2100 D Product Information ENERGY LABELLING 5 EN...

Page 6: ...SLE SLE Plus A1007847 661Y2100 D Product Information RATING PLATE EN 6...

Page 7: ...ostat 60 80 C to set the domestic hot water DHW temperature 2 Manual reset high limit thermostat to restart the tank after overheating of the primary circuit 3 Connection plug to connect the electrica...

Page 8: ...to heat by transfer fluid or independently with an optional electric resistance 1 Manual air bleed valve 2 Polypropylene shell 3 Dip tube 4 Electrical heating element optional 5 Outer steel tank prim...

Page 9: ...20 1280 F mm 430 430 525 G mm 320 320 405 320 320 380 H mm 240 240 230 240 240 235 Smart E 130 Smart E 160 Smart E Smart E Plus 210 Smart E Smart E Plus 240 Smart E Smart E Plus 300 Max operating pres...

Page 10: ...electrical heating element connection 6 Heating return connection heat pump 7 Flow heating circuit except Smart E 130 160 8 Return heating circuit except Smart E 130 160 1 Cold water inlet connection...

Page 11: ...e temperature 10 C MAIN CHARACTERISTICS Main Characteristics Smart E 130 Smart E 160 Smart E Smart E Plus 210 Smart E Smart E Plus 240 Smart E Smart E Plus 300 Total capacity L 130 161 203 242 293 Pri...

Page 12: ...thermostat of the tank cannot control the heating element To be mounted with an external box with a switch and a circuit breaker not included in the delivery Volt Amp Power Code 1 x 230 V 13 3 kW 1080...

Page 13: ...fter removal of pack aging check the package contents and that the appliance is free of damages Contents packaging A domestic hot water tank A technical manual One energy label TOOLS REQUIRED FOR THE...

Page 14: ...ion connect the stainless steel tank directly to the earth Use an adjustable earth clamp see example below on one of the DHW connections to connect to the earth Advised copper wire section 2 5mm Make...

Page 15: ...eria exists including Legionella pneumophila if a minimum temperature of 60 C is not maintained in both the DHW tank and the hot water distribution network Essential instructions for the electrical sa...

Page 16: ...used Discharge pipe D2 can now be plumbed into the soil stack but only soil stacks that can handle temperatures of 99 C or greater should be used Extract from The Building Regulation G3 Discharge pip...

Page 17: ...e pipe size larger than the largest individual discharge pipe D2 to be connec ted 3 60 The discharge pipe should not be connected to a soil discharge stack unless it can be demonstrated that that the...

Page 18: ...2 tundish with continuous fall See 3 56 Table G3 and worked example Tundish Discharge below fixed grating 3 61 gives alternative points of discharge Fixed grating Trapped gulley V a l v e o u t l e t...

Page 19: ...t largest size Maximum resistance allowed for a straight length of 28mm pipe D2 from a G1 2 temperature relief valves equates to 18m Subtract the resistance of 4 No 28mm elbows at 1 0m each 4 0m There...

Page 20: ...he appropriate size Make sure that the circuit between the tank and the safety valve is always open The third DHW tank connection if any can be used for the auxiliary DHW loop If the connection is not...

Page 21: ...ixing valve 12 Air vent Cold water Hot water Domestic hot water kit option 1 Thermostatic mixing valve 2 Mixed water outlet 3 4 M 3 DHW expansion vessel connection 3 4 M 4 Safety unit 7 bar 5 Outlet h...

Page 22: ...ON TO THE PRIMARY CIRCUIT 1 Primary circuit filling valve 2 Charging pump 3 Check valve 4 Primary circuit stop valve 5 Expansion vessel 6 Pressure gauge 7 Safety valve set at 3 bar 8 Drain valve 9 Sto...

Page 23: ...0 D Installation EXAMPLES OF POSSIBLE COMBINATIONS OF THE SMART E AND SMART E PLUS Smart E Plus combined with a heat pump and floor heating system Smart E 210 240 300 combined with a boiler and floor...

Page 24: ...bled 1 System filling valve 2 Safety valve set at 3 bar 3 Expansion vessel 4 Isolation valve heating system 5 Pressure gauge Essential instruction for the correct operation of the installation Connect...

Page 25: ...to the ratio recommended in the local regulations Consult the manufacturer to determine the compatibility of the antifreeze with the tank s construction materials Essential instructions for the correc...

Page 26: ...oiler 3 Open the air bleed valve 4 located on the top of the hot water tank 4 When the air is eliminated close the air bleed valve 4 Make sure the air bleed valve is tight FILLING Essential instructio...

Page 27: ...SLE SLE Plus A1007847 661Y2100 D Starting Up 27 EN Cold water Hot water Figure 1 1 3 3 2 Figure 2 1 2 4 3 1 2...

Page 28: ...orrectly connected and not leaking Check that the sensor of the thermostat is correctly positioned in the dry well see figures below STARTING UP If the tank is used as electric DHW tank only 1 Put the...

Page 29: ...y unit drips periodically it may be due to an expansion problem or clogging of the valve For internal inspections the hand hole can be used If there is none use one of the water connections to insert...

Page 30: ...ain the primary circuit of the hot water heater 1 Stop the charging pump 2 Isolate the primary circuit by closing the stop valves 1 3 Connect the drain valve 2 to the sewer using a flexible hose 4 Ope...

Page 31: ...op valve 4 3 Connect the drain valve 2 to the sewer using a flexible hose 4 Open the drain valve 2 and the air vent 5 to drain the water from the DHW tank to the sewer 5 Close the drain valve 2 and th...

Page 32: ...stat of the tank 3 Check if the charging pump works properly and replace if necessary 4 Check the safety thermostat on the tank and or the electric heating element and reset or replace if neces sary 5...

Page 33: ...SLE SLE Plus A1007847 661Y2100 D 33 EN...