1. Engage the spring-loaded mechanism of the mounting clips on the device by hooking the clip onto
the bottom edge of the DIN-rail and applying slight pressure upwards.
2. As bottom portion engages, tilt the upper hook towards the DIN-rail.
3. Release the spring mechanism once the unit is mounted on the rail.
Conditioning and Powering the Unit
1. Once the device is connected to the cold-water line, Flush the unit at 4 L/min (1.05 Gallons/
min) for 1 minute to ensure water entirely floods the disinfection unit. During this time, ensure all
connections are tight and sealed.
2. Connect the DC power source or AC to DC power adapter to the device. Hand-tighten the nut to
the threaded jack to secure it.
3. If there is no water flow on powering up, the Acuva logo should glow green for 30 seconds.
4. Turn on the faucet. The logo will glow blue which indicates the water purification is in progress. If
the smart faucet is installed, its base will glow blue as well.
5. Turn off the faucet and the device will automatically go into standby mode.
WARNING
Do not use a wrench or pliers to tighten the plug, power jack or inlet/outlet fittings as this
may cause damage to the device. Contact Acuva for support.
For DC power source applications, installing a 3A 250V slow blow fuse will provide additional electrical protection
INSTALLATION GUIDE
Mounting the Unit
recommended orientation
Recommended
Not Recommended
Spring-Loaded
Mechanism
DIN-rail