Acuva Eco Installation Instructions Download Page 4

 

 

  

 

 

Acuva Technologies Inc. #162-2366 Main Mall, Vancouver BC V6T 1Z4 Canada     www.acuvatech.com 

 

1.2

 

: Faucet Installation 

(Faucet installation parts not shown on Fig.4)

 

 

1.

 

Drill a 3/4

” 

hole into the counter top.  

2.

 

Thread the faucet power cord into the 3/4

” 

hole, and insert the faucet stem into the hole. 

12.

 

Thread the faucet power cord through its plastic spacer under the counter to ensure that 
the cord is not pinched against the counter when the faucet is fastened into place, making 
sure that the spacer seal is facing up to seal against the counter. 

3.

 

Add the plastic faucet fastener to the faucet stem and tighten the fastener against the 
spacer to secure the faucet into place, while making sure that the faucet is positioned 
properly as required. 

4.

 

T

o connect the ¼” water line to the faucet stem,

 slip the hex nut onto the tube, followed 

by the plastic ferrule and plastic tube support. Insert the tube  end and ferrule into the 
bottom of the faucet stem and tighten the hex nut by hand until resistance is felt, then 
tighten with a wrench while being careful not to over-tighten. 

 

1.3

 

Final Installation Steps

 

1.

 

Once the UV device is connected to the faucet with PEX tubing, plug the faucet power 
cord into its Jack on the UV device. 

2.

 

Once the faucet power cord is connected to the UV device, connect the 12V DC power 
source to the UV Chamber Unit Power Jack.  

3.

 

Activate the cold-water pressure in the plumbing system. 

4.

 

Turn on the faucet. (When water is flowing, the blue light on the device will come on 
steady which indicates the water purification is in progress as seen in Figure 6) 

5.

 

Keep the faucet on to flush the system for 5 minutes to release all the air pocket and 
bubbles and the water flows smoothly. 

6.

 

Once all the bubbles are released, turn off the faucet and the device will automatically go 
into standby mode. 

7.

 

At this point, the device is ready for regular use.

 

 

2.

 

Maintenance 

The Acuva UV-LED Water Purification Systems are designed to give years of trouble free service. 
Using  state-of-the-art  long-life  UV-LEDs,  there  are  no  mercury  bulbs  to  replace  and  dispose 
annually. However, there are some simple tasks that should be performed to ensure continued 
trouble-free operation. 

 

Summary of Contents for Eco

Page 1: ...Acuva Technologies Inc 162 2366 Main Mall Vancouver BC V6T 1Z4 Canada www acuvatech com Installation Instructions Acuva Eco UV LED Water Purifier Acuva Arrow UV LED Water Purifier ...

Page 2: ... The Acuva Arrow system has a built in flow regulator while only the Acuva Eco requires a flow restrictor Item No 11 in Figure 4 The Acuva Arrow has a built in flow sensor and is activated with the flow of water while the Acuva Eco is manually activated with the Acuva Smart Faucet Item No 12 in Figure 4 Fig 4 Plumbing Diagram Fig 5 Mounting the UV Chamber to the Din Rail Fig 6 UV Indicator Light ...

Page 3: ...e Tee as far as possible and pull slightly to assure that the seal is secure 5 To install the Pre Filter wrap the threads of the 3 8 OD MNPT Adapters Item no 5 with Teflon Tape and screw these adapters into the 2 female ends of the pre filter connect the 3 8 PEX tube from the Tee into the inlet side of the pre filter while making sure that water will flow in the proper direction as indicated on th...

Page 4: ...ance is felt then tighten with a wrench while being careful not to over tighten 1 3 Final Installation Steps 1 Once the UV device is connected to the faucet with PEX tubing plug the faucet power cord into its Jack on the UV device 2 Once the faucet power cord is connected to the UV device connect the 12V DC power source to the UV Chamber Unit Power Jack 3 Activate the cold water pressure in the pl...

Page 5: ...Warning Failure to properly winterize the device before it is exposed to freezing temperatures can lead to damage and water leakage To prevent freezing pump a non toxic antifreeze into the water system Open the point of use faucet connected to the Acuva device and continue to pump non toxic antifreeze until you see the antifreeze coming out of the faucet In the spring remember to flush with fresh ...

Reviews: