3-in-1 Sensor Installation Guidelines

INSTALLATION HEIGHT  

Mount the sensor at least 5 feet (1.5 meters) off the 

ground (higher is better for wind measurement) in an open area. Secure to 

fence post, 2”x4“ wood, 3/4” pole, etc. (not included)

LEVEL INSTALLATION 

 Use a bubble level (not included) to ensure level 

installation for accurate wind measurement.

Top or Side Mount

1. Insert the mounting base into the 

hole on the bottom of the sensor.

2. Use one of the screws included in 

the hardware bag to fasten the 

lower sensor housing to the 

mounting base.

3. Make sure the sensor is level using 

a bubble level.

4. Fasten mounting base to a post or 

railing using 2 screws.

Pole Mount

1. Insert 3/4” schedule 40 PVC (25.8 mm 

O.D.) pole (not included) or similar item 

all the way into the hole on the bottom of 

the sensor. Note: Mounting base not used.

2. Use one of the screws included in the 

hardware bag to fasten the lower sensor 

housing securely to the pole.

3. Make sure the sensor is level using a 

bubble level.

The 3-in-1 sensor is now ready to use.

Basic Setup is Complete

The 3-in-1 sensor will now synchronize with the display unit. It may take a few 

minutes for synchronization to complete. If both or one of the units appear to 

be functioning improperly, please refer to the troubleshooting section.

Top Mount

Side Mount

Pole Mount

Do not install during 

electrical storms. Do 

not place pole or 

sensor near 

electrical lines or 

electrical equipment.

11

OPERATION

Using the Weather Center
Learning Mode

Self-Calibrating Forecasting use a unique algorithm to analyze changes in 

pressure and temperature over a time period (called Learning Mode) to 

determine your altitude. After 14 days, the Learning Mode icon disappears 

from the display screen. At this point, the self-calibrated pressure is tuned in to 

your location and the unit is ready for superior weather prediction.

Weather Forecast

AcuRiteʼs patented Self-Calibrating Forecasting provides your personal forecast 

of weather conditions for the next 12 to 24 hours by collecting data from the 

sensor in your backyard. It generates a forecast with pinpoint accuracy - 

personalized for your exact location.

Barometric Pressure

Subtle variations in barometric pressure greatly affect the weather. This 

weather center displays the current pressure with an arrow icon to indicate the 

direction the pressure is trending (FALLING, STEADY, or RISING).

High & Low Records

The Record Highs & Lows button (    ) displays minimum and maximum 

recordings for outdoor and indoor temperature and humidity. To select 

between viewing daily (since midnight) or all-time records, slide the switch 

located on the back of the display. To reset low records, press and hold the 

(     ) button while viewing low records. To reset high records, press and hold 

the (     ) button while viewing high 

records.

Wind Speed

The Wind area of the display features 

WIND SPEED PEAK, AVERAGE, 

CURRENT WIND SPEED, and a graphic 

representation of current wind speed. 

There is also a time stamp for the last 

wind speed reading.

View the complete list of icons at www.AcuRite.com/acurite-icons

EXAMPLE

OF WEATHER

FORECAST

DISPLAY

ICONS

RAIN

LIKELY

RAIN/SNOW

MIX LIKELY

SNOW

LIKELY

LIGHT SNOW

LIKELY

MOSTLY

CLOUDY

CLOUDY

LIGHT RAIN

LIKELY

PARTLY

CLOUDY

CLEARING

(flashing=stormy)

(flashing=stormy)

Summary of Contents for 00608BPDI

Page 1: ...y Instrument Co Lake Geneva WI 53147 All other trademarks and copyrights are the property of their respective owners AcuRite uses patented technology Visit www AcuRite com patents for details Questions Contact Customer Support at 877 221 1252 or visit www AcuRite com CONTENTS Unpacking Instructions 2 Package Contents 2 Product Registration 2 Features Benefits 3 in 1 3 Features Display Unit 4 Setup...

Page 2: ... film that is applied to the LCD screen prior to using this product Locate the tab and peel off to remove Package Contents 1 Display unit with tabletop stand 2 3 in 1 sensor 3 Sensor mounting bracket 4 Mounting hardware 5 Instruction Manual www AcuRite com Register online to receive 1 year warranty protection PRODUCT REGISTRATION Register a Product IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE W...

Page 3: ...ase Lever for Battery Access 3 Mounting Point 4 Wind Speed Anemometer 5 Mounting Hardware Includes anchors and screws Qty Diameter Length 4 4 1 2 6 3 8 6 Mounting Bracket 7 A B C Switch not shown ID code that must match displayʼs A B C switch to ensure units synchronize 4 1 2 3 6 5 ...

Page 4: ...52 info chaney inst com Register your Product Submit Feedback Ideas Support User Forum Installation Videos Replacement Parts Instruction Manuals 24 7 support at www AcuRite com normal wear and tear been damaged including by acts of nature tampered abused improperly installed damaged in shipping or repaired or altered by others than authorized representatives of Chaney The above described warranty ...

Page 5: ...quipment Such modifications could void the user authority to operate the equipment This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two confitions 1 This device may not cause interference and 2 This device must accept any interference received including interference that may cause undesired operation of the device DISPLAY UNIT 1 Wireless...

Page 6: ...eadings can be calibrated on the display unit to improve accuracy Calibration can improve accuracy when 3 in 1 sensor placement or environmental factors impact your data accuracy 1 Locate the SET and buttons on the back of the display unit Press AND HOLD all three buttons for at least 5 seconds 2 The temperature will begin flashing indicating it is ready to be calibrated 3 Press the up or down arr...

Page 7: ...BATTERY SAFETY Clean the battery contacts and also those of the device prior to battery installation Remove batteries from equipment which is not to be used for an extended period of time Follow the polarity diagram in the battery compartment Promptly remove dead batteries from the device Dispose of used batteries properly Only batteries of the same or equivalent type as recommended are to be used...

Page 8: ...E ºF or ºC UNITS PRESSURE inHg or mb UNITS WIND SPEED mph kph knots You will automatically exit SET MODE if no buttons are touched for 30 seconds Enter basic setup mode at any time by pressing the SET button If you live in an area that observes Daylight Saving Time DST should be set to ON even if it is not currently Daylight Savings Time 13 Inaccurate temperature or humidity Make sure both the dis...

Page 9: ...calibrates for a total of 33 days Troubleshooting 12 9 Placement for Maximum Accuracy AcuRite sensors are sensitive to surrounding environmental conditions Proper placement of both the display unit and the sensor are critical to the accuracy and performance of this product Important Placement Guidelines Display unit and sensor must be within 330ft 100m of each other MAXIMIZE WIRELESS RANGE Place u...

Page 10: ...ue algorithm to analyze changes in pressure and temperature over a time period called Learning Mode to determine your altitude After 14 days the Learning Mode icon disappears from the display screen At this point the self calibrated pressure is tuned in to your location and the unit is ready for superior weather prediction Weather Forecast AcuRiteʼs patented Self Calibrating Forecasting provides y...

Reviews: