16
PowerBrick
TM
6.0
Power Ignition Shutdown Procedure
Power Management
•
Power‐off delay time is selectable by Software to disable and enable in 0‐255 minutes
•
Ignition On/Off status detectable by SW
•
If the ignition is off and the system is still on after 3 Sec, PowerBrick
TM
6.0 will shut down
automatically.
•
If the ignition is turned on again and the power‐off delay is in progress, PowerBrick
TM
6.0 will
cancel the delay function and will continue to operate normally.
•
If the ignition is turned on again and the power‐off delay ended, PowerBrick
TM
6.0 will shut
down completely will power‐on again automatically.
Check IGN Status
IGN OFF (LOW)
Check Delay Time
(ON/OFF)
3sec time off delay
Delay Time on 0-
255 minutes
setting by software
OS Shutdown
System
Shutdown
from IGN OFF
System is OFF
after 3sec