Acuity Brands Sensor Switch WSX Series Quick Start Manual Download Page 2

2 of 4

Sensor Switch    900 Northrop Road, Wallingford, CT 06492     Phone: 1.800.PASSIVE      sensorswitch.com     ©2013 Acuity Brands Lighting, Inc.     All rights reserved 07/01/13

WSX 

Family

On Mode

Restore

Factory

Defaults

Switch

Mode

LED

Operation

Predictive

Exit

Time

Microphone

Grace Period

Occupancy

Time

Delay

Photocell

Set-Pt

Minimum

On Time

Manual On

Grace

Period

Dual

Technology

(Microphonics

TM

)

Predictive

Grace

Time

4x

5x

7x

9x

10x

2x

3x

12x

11x

13x

15x

16x

PRESS BUTTON

3.

While LED 

flashes

back current

setting 10x...

OPERATIONAL SETTINGS

  _________________________________________________________________________________________________

PROGRAMMING INSTRUCTIONS

  ______________________________________________________________________________________

4.

PRESS BUTTON

30 sec

20 min

30 min

17.5 min

15.0 min

12.5 min

10 min

5.0 min

2.5 min

7.5 min

1x

13x

2x

3x

4x

5x

6x

7x

8x

9x

1.

While LED 

flashes back new

setting 10x...

5.

6.

On Mode

Restore

Factory

Defaults

Switch

Mode

LED

Operation

Predictive

Exit

Time

Microphone

Grace Period

Occupancy

Time

Delay

Photocell

Set-Pt

Minimum

On Time

Manual On

Grace

Period

Dual

Technology

(Microphonics

TM

)

Predictive

Grace

Time

4x

5x

7x

9x

10x

2x

3x

12x

11x

13x

15x

16x

PRESS BUTTON

4.

1.

5.

6.

LED FLASHES

CONFIRMATION

TWICE

PROGRAMMING

COMPLETE

7.

7.

 Operational settings can be changed via the push-button sequence outlined below (note the example used is for changing occupancy time delay). Programming for 2P units done with each 

pole’s  corresponding push-button.

e.g., 5 flashes is default

10 min time delay

e.g., press 4x 
    to change 

      to 7.5 min

e.g., 4 flashes 
indicates new 

7.5  min time 

delay setting

e.g., press 2x to 
save and exit

2.

3.

e.g., press 2x for  
        Occupancy Time  
              Delay

NOTE: (

*

) Indicates factory default (unless otherwise marked)

2

   

=  Occupancy Time Delay

Time sensor keeps lights on after last occupancy detection.

 

1  

30 sec    

4  

7.5 min      

7

  15.0 min     

13

  30.0 min

 

2

  2.5 min   

5  

10.0 min*   

8

  17.5 min 

 

3

  5.0 min   

6  

12.5 min    

9  

20.0 min

For additional time settings, contact technical support at 

1.800.PASSIVE

3

   

=  On Mode

Automatic On turns lights on when occupancy is detected. Manual 

On requires a button press to turn the lights on. Reduced Turn-On 

directs the sensor to only turn on when a large motion, such as 

a person entering a room, is detected. Weaker signals, such 

as reflections from glass, are ignored. Once lights are on, the 

sensor returns to maximum sensitivity.

 

1

  Automatic On    

2

  Manual On       

3

  Reduced Turn-On

 

Settings 1 & 3 not available on -VA (Vacancy only) sensors. 
Notes on Default Settings

•  WSX (PDT) Series default: Automatic On

•  Default for units with -SA, -VA, or -NL option: Manual On

•  WSX (PDT) 2P Series default: Pole 1 Auto On, Pole 2 Manual 

•  Default for 2P units with -2SA, -2VA, or NL options: 

      Both poles Manual On

 

4

   

=  Switch Modes

These modes dictate switch functionality. 

Pressing the button in Override Off mode (setting 1) turns off 

and keeps lights off until pressed again. 

Disabling the Switch (setting 2) prevents the button from turning 

the lights on. (continued next column) 

Predictive Mode (setting 3) determines if a user has left the room 

after the lights are switched off. It does this by monitoring the 

space for a period after the button is pressed (Predictive Grace 

Time), following a delay to allow exiting the room (Predictive Exit 

Time). If occupancy is detected the device will disable Auto-On 

& hold the lights off until manually switched. If no occupancy is 

detected the sensor instantly reverts to auto-on mode.
If Predictive Mode with Expiration (setting 4) is enabled, once 

the sensor has disabled Auto-On it will continue to monitor the 

space. When no occupancy is detected for a duration equal to the 

occupancy time delay, the sensor will revert to Auto-On mode. 

    

1

  Override Off ** 

 

2

  Switch Disable

 

3

  Predictive Mode

 

4

  Predictive Mode with Expiration*

*  Default for WSX (PDT) units & Pole 1 of WSX (PDT) 2P units

**  Default for units with -SA, -VA, or -NL options, Pole 2 of WSX         

     (PDT) 2P units, and both poles of 2P units with -2SA, -2VA, 

     or -NL options

5

   

=  Photocell Set-Point

The ambient light level at which the sensor prevents the lights 

from initially turning on. Once on, the lights will remain on until 

the occupancy time delay expires and turns them off. 

 

1  

Disabled*  

5

  2 fc                

9  

32 fc

 

2

  Auto Setpoint 

6  

4 fc 

     

10  

64 fc

 

3

  0.5 fc 

 

7  

8 fc  

           

 

4

  1 fc 

 

8  

16 fc 

         

             

Note: Sensor changes to Auto On mode if photocell is enabled. 

Photocell not present in -NL versions.

7

 

=  LED Operation

Indicates behavior of device’s LED.

 

1

  Occupancy Indication*      

Disabled 

 

2  

Relay Indication                

4

 Override On***

*Standard Factory Default     *** Factory Default for -NL version

 

9

  

=  Restore Factory Defaults

Returns all functions to original settings.

 

1

  Maintain Current* 

2  

Restore Defaults

10

  

=  Minimum On Time

Required initial time for lamps to be on after each switch on, 

regardless of occupancy status. Once met, lights resume 

following occupancy time delay. 

  

1

  0 min (disabled)* 

3  

30 min         

5  

60 min

 

2

  15 min                      

4  

45 min 

 

11  =  Manual On Grace Period

Time period after lights automatically turn off that they can be 

reactivated by motion. (Manual On (Semi-Auto) mode only)

 

  

1

  0 sec                 

2  

Unused       

3

  15 sec*

12

    

=  Dual Technology (Microphonics

TM

)

Relative responsiveness of Microphonics detection. 

  

1

  Normal*             

3

  Medium       

5

  Phase Off    

    

2

 Off

                     4

  Low                 (15-10-5 min)

13   =  Microphone Grace Period

Time period after lights are automatically turned off that they 

can be voice reactivated.

 

1

  0 sec 

3

  20 sec 

5

  40 sec 

7

  60 sec

 

2

  10 sec* 

4

  30 sec 

6

  50 sec 

15  =  Predictive Exit Time

Time period after manually switching lights off for occupant to 

leave the space.

 

1

  5 sec       

3

  7 sec       

5

  9 sec        

7

  15 sec        

9

  30 sec

 

2

  6 sec      

4

  8 sec       

6

  10 sec*    

8

  20 sec 

16  =  Predictive Grace Time

Time period after Predictive Exit Time that sensor rescans the 

room for remaining occupants.

 

      

1

  0 sec         

3

  10 sec         

5

  30 sec*       

7

  50 sec 

      

2

  5 sec         

4  

20 sec         

6

  40 sec        

8

  60 sec