READ AND FOLLOW ALL SAFETY INSTRUCTIONS!

SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION 

· 

To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/

abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and 

all fixture labels.  

· 

Before installing, servicing, or performing routine maintenance upon this equipment, follow these general 

precautions.

· 

Installation and service of luminaires should be performed by a qualified licensed electrician. 

· 

Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and 

operation and any hazards involved.  Regular fixture maintenance programs are recommended. 

· 

It will occasionally be necessary to clean the outside of the refractor/lens.  Frequency of cleaning will depend on 

ambient dirt level and minimum light output which is acceptable to user.  Refractor/lens should be washed in a 

solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry.  

Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing 

damaged gaskets as necessary. 

· 

DO NOT INSTALL DAMAGED PRODUCT!  This luminaire has been properly packed so that no parts should have 

been damaged during transit. Inspect to confirm.  Any part damaged or broken during or after assembly should 

be replaced.

· 

Recycle: For information on how to recycle LED electronic products, please visit 

www.epa.gov

·

 

These instructions do not purport to cover all details or variations in equipment nor to provide every possible 
contingency to meet in connection with installation, operation, or maintenance.  Should further information 
be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s 
purposes, this matter should be referred to Acuity Brands Lighting, Inc. 

 

Disconnect or turn off power before installation or 

servicing.

 

Verify that supply voltage is correct by comparing it with 

the luminaire label information.

 

Make all electrical and grounded connections in 

accordance with the National Electrical Code (NEC) and 

any applicable local code requirements.

 

All wiring connections should be capped with UL 

approved recognized wire connectors.

WARNING

RISK OF ELECTRIC SHOCK

 

Allow lamp/fixture to cool before handling. Do not 

touch enclosure or light source.

 

Do not exceed maximum wattage marked on 

luminaire label. 

 

Follow all manufacturer’s warnings, recommendations 

and restrictions for: driver type, burning position, 

mounting locations/methods, replacement and 

recycling.   

WARNING

RISK OF BURN

CAUTION

RISK OF FIRE

 

Keep combustible and other materials that can burn, 

away from lamp/lens.  

 

Do not operate in close proximity to persons, 

combustible materials or substances affected by heat 

or drying. 

CAUTION

RISK OF INJURY

 

Wear gloves and safety glasses at all times when 

removing luminaire from carton, installing, servicing or 

performing maintenance.

 

Avoid direct eye exposure to the light source while it is on.

Summary of Contents for Lithonia HLF1

Page 1: ...laced Recycle For information on how to recycle LED electronic products please visit www epa gov These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for t...

Page 2: ...t factory wired to the luminaire must be checked for compatibility with the luminaire prior to installation Never connect an LED product directly to a dimmer pack that has not been pre approved LED fixtures must be powered directly off a switched circuit Unless individual product specifications deem otherwise Do not restrict fixture ventilation Allow for some volume of airspace around fixture Avoi...

Page 3: ...received the correct merchandise 5 year limited warranty Lithonia Lighting Outdoor One Lithonia Way Conyers Georgia 30012 Phone 800 279 8041 Fax 770 918 1209 www lithonia com 2011 Acuity Brands Lighting Inc All rights reserved HLF YOKE Yoke Mounting Plate Template Note This drawing is NOT to scale and should be used for dimensional purpose only HLF1 HLF2 Tools Required 9 16 5 8 3 4 and 1 4 wrench ...

Page 4: ...8 32 screws in holes located on both sides of the as sembly 2x HLF1 4x HLF2 Part Number RJ521380 Rev B Revision Date 4 4 16 IS ships installed Remove the access cover plate to the integral wiring compartment using a 1 4 hex socket or regular screwdriver Slip integral slipfitter onto tenon ensuring that the wires are pulled through the integral wiring compartment without pinching Secure the slipfit...

Page 5: ... for any reason drill no deeper than 1 2 with a 147 26 diameter drill Driver Access THE FIXTURE SHOULD NOT BE ENERGIZED DURING ANY ELECTRICAL WORK The driver is pre wired so access to the driver during installation is unnecessary Open the fixture by loosening the four hex key screws on the driver box cover and rotate the driver box cover away from housing to open Ensure the fixture is not energize...