6. 

Aim fixture as required and tighten the 7/16-14 SHC knuckle adjustment bolt using an approximately 

38 ft-lbs. (See figure 14) For units with photocontrol receptacle, the fixture mounting/aiming angle must be 

restricted from 0° to 45° from horizontal per ANSI C136.10-2010.

7. 

Energize the luminaire to verify its operation and proper illumination of area.

WARNING: DO NOT MOUNT THE KNUCKLE FITTER TO A TENON OR BRACKET THAT IS MORE 

THAN 5 DEGREES FROM VERTICAL. MOUNTING AT AN ANGLE GREATER THAN 5 DEGREES RE-

QUIRES USE OF A PROPERLY TIGHTENED THRU-BOLT AND LOCKNUT. FAILURE TO CORRECTLY 

INSTALL COULD RESULT IN SERIOUS INJURY OR DEATH.

Figure 14

Emergency

Magnetic Switch

Summary of Contents for AARP

Page 1: ...aced Recycle For information on how to recycle LED electronic products please visit www epa gov These instructions do not purport to cover all details or variations in equipment nor to provide every p...

Page 2: ...minaire that are not factory wired to the luminaire must be checked for compatibility with the luminaire prior to installation LED fixtures must be powered directly off a switched circuit Unless indiv...

Page 3: ...s device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference rec...

Page 4: ...r 8 Lithonia drilling pattern and has 3 holes The top and bottom hole are threaded b The longer bar has one top hole and a slot with a slid ing threaded hole to be used on poles with existing drill pa...

Page 5: ...second bolt through the arm slot and into the available threaded hole of the mounting bar See Fig 4 5 The luminaire is supplied with a clearance slot in the back to allow wires to be pulled into the...

Page 6: ...Tools Required 5 8 Socket wrench 3 16 Allen wrench 5 32 Allen wrench Minimum tenon pole diameter 2 schedule 40 pipe 2 3 8 OD 1 Slip luminaire Mast Arm Mount over 2 3 8 pole tenon See Figure 7a 2 Use...

Page 7: ...e set screws enough to flip the luminaire over as shown below in figure 8a then loosen the six captive screws on door to access the wire connection area Remove the rubber grommet see figure 8b before...

Page 8: ...ground connection and lock it Repeat this step for black hot and white neutral wires Select matching colored wires coming from SPD See Figure 9a 9b 9c 6 Use cable tie and bundle all newly attached wir...

Page 9: ...ided 7 16 14 x 4 1 2 bolt through Mast Arm Mount and drilled 1 2 hole on tenon and place provided 7 16 nut onto bolt see figure 12 and tighten securely to 45 50 ft lbs 9 Evenly tighten the Six 6 3 8 1...

Page 10: ...the splice access cover and pull supply wire leads from knuckle cavity See figures 13a and 13b 2 Slip luminaire knuckle fitter over 2 3 8 pole tenon and evenly tighten the six 6 3 8 16 UNC knuckle ten...

Page 11: ...oximately 38 ft lbs See figure 14 For units with photocontrol receptacle the fixture mounting aiming angle must be restricted from 0 to 45 from horizontal per ANSI C136 10 2010 7 Energize the luminair...

Page 12: ...BA and secure to wall with secure base plate to wall with 4 1 4 diameter fasteners not included with luminaire using the 4 holes located on the outer corners of the base plate Check the base plate to...

Page 13: ...ge components and void warranties 6 Make sure no wires are pinched and tuck excess wire up into the luminaire mounting area and reinstall the SPA Cover that was removed in step 3 Tighten the two cover...

Page 14: ...is mounted securely to the pole the angle of the luminaire can be safely adjusted 3 If the luminaire angle will be adjusted DO NOT pull the luminaire supply wires taut leaving slack in the input wires...

Page 15: ...Screwdriver AAWSC only Minimum Square Pole 3 5 Face Minimum Round Pole 3 2 Diameter CAUTION APPLY A CONTINUOUS BEAD OF WEATHER PROOF CAULKING BETWEEN MOUNTING BASE PLATE AND WALL TO ENSURE WEATHER TI...

Page 16: ...om set screws to the same length 5 Now alternating between the top and bottom sets of set screws gently tighten until snug If the base plate was installed level approximately 1 threads should be visib...

Page 17: ...ult setting is maximum output install luminaire as normal 1 Loosen six captive screws and remove RSX door to access the luminaire electronics Fig 23 Set aside for reinstallation 2 In all RSX family lu...

Page 18: ...lithonia com Part Number IM 459 Rev A Revision Date 8 29 19 3 Make sure that wires and door tethers are not pinched and that the door gasket is still snugly in its groove on the door Re install the mo...

Reviews: