6.12 Diagnosis with the Online Monitor (OLM)
483
Nominal status of
the axes (Plc Nom
State)
The nominal status of the axes is requested by the PLC.
To select the
PLC Nom State
function:
Press the
Login Ipo
key.
Press the
Axes
key.
Press the
Plc Nom state
key.
The function displays the status of the following binary variables (the descrip-
tions refer to the status “true”):
Variable
Display
RpfNocken
Trip dog for reference end position
IstSollwUebern
Transfer the current values as nominal values.
ClampRequest
Request for clamping this axis.
PosCtrlRequest
Request for position feedback control for this axis
KeineUeberw
No monitoring of following error or standstill
VorschubFreigabe
Feed rate stop is not set
AntriebEin
Request to switch the drive on
IstSollUeberStrobe
Not used
CurrentOff
Switch off the current for wye/delta connection