ACU-RITE 1502 Instruction Manual Download Page 10

Placement for Maximum Accuracy

AcuRite sensors are sensitive to surrounding environmental conditions. Proper 

placement of both the display unit and the sensor are critical to the accuracy 

and performance of this product.

Important Placement Guidelines

Display unit and sensor must be within 330ft (100m) of each other. 

MAXIMIZE WIRELESS RANGE

Place units away from large metallic items, thick walls, metal surfaces, or other 

objects that may limit wireless communication.

PREVENT WIRELESS INTERFERENCE

Place both units at least 3ft (.9m) away from electronic devices (TV, computer, 

microwave, radio, etc.).

LOCATE AWAY FROM HEAT SOURCES

Position sensor away from heaters, air conditioners, chimneys, exhaust vents, 

asphalt and concrete (surfaces that radiate heat).

LOCATE AWAY FROM HUMIDITY SOURCES

Avoid installing the sensor near pools, spas, or other bodies of water. Water 

sources may impact humidity accuracy. 

LOCATE AWAY FROM SPRINKLER HEADS

DO NOT install the sensor where it will be sprayed by a sprinkler system. This 

impacts rainfall measurement accuracy and may force water inside the sensor.

LOCATE AWAY FROM WIND & RAIN OBSTRUCTIONS

DO NOT mount the sensor with obstructions above it, as this 

will impact rainfall measurement. Consider a location that is 

a wide open area, with few structures around to ensure 

accurate wind speed and direction measurements.

5-in-1 Installation Guidelines

INSTALLATION HEIGHT  

Mount the sensor at least 5 feet (1.5 meters) off the 

ground (higher is better for wind measurement) in an open area. Secure to 

fence post, 2”x4“ wood, 3/4” pipe, etc. (not included)

LEVEL INSTALLATION 

 Use the bubble level on the top of the sensor to ensure 

level installation for accurate wind and rain measurement.

SOLAR CELL ORIENTATION  

Install the sensor with the 

solar cell facing SOUTH

. This 

ensures the cell receives as much sun as possible, and orients wind direction.

11

10

5-in-1 Sensor Installation

1. Fasten mounting base (included) 

to a post or pole (not included) 

using the 4 longer screws 

included in the hardware bag.

2. Insert the mounting base into the 

hole on the bottom of the sensor. 

3. Make sure the arrows on the top 

of the sensor are pointed in the 

proper direction and the bubble 

level is centered. The solar cell 

should be facing south to 

properly orient the wind 

direction vane.

3. Fasten the sensor into the 

mounting base using the 2 

shorter screws included in the 

hardware bag. 

The 5-in-1 sensor is now

ready to use.

Visit us online to view installation photos and 

video, or learn more about AcuRite technology:

www.AcuRite.com/5in1

SOUTH

(1.5 meters)

NO OBSTRUCTIONS

ABOVE OR AROUND

Display Unit Placement

Place the display unit in a dry area free of dirt and dust. To 

ensure accurate temperature measurement, place out of direct 

sunlight and away from heat sources or vents. Display unit stands 

upright for tabletop use or is wall-mountable. 

C

C

View Video

Clear Data Collected During Installation

When installation is complete,  clear erroneous data from the display unit by 

pressing the “CLEAR TODAY” button, on the back of the display unit inside the 

battery compartment. This button will clear data recorded since 12:00am.

Basic Setup is Complete

The 5-in-1 sensor will now synchronize with the display unit. It may take a few 

minutes for synchronization to complete. If both or one of the units appear to 

be functioning improperly, please refer to the troubleshooting section.

5-in-1 Sensor Placement

The 5-in-1 sensor is designed to remain outdoors all year long. 

Choose an open location with no obstructions above or around 

the sensor for the most accurate measurements.

Summary of Contents for 1502

Page 1: ...aney Instrument Co Lake Geneva WI 53147 All other trademarks and copyrights are the property of their respective owners AcuRite uses patented technology Visit www AcuRite com patents for details Questions Contact Customer Support at 877 221 1252 or visit www AcuRite com CONTENTS Unpacking Instructions 2 Package Contents 2 Product Registration 2 Features Benefits 3 Setup 6 5 in 1 Sensor Setup 6 Dis...

Page 2: ...ures which have received Limited One Year Warranty Customer Support AcuRite customer support is committed to providing you with best in class service For assistance please have the model number of this product available and contact us in any of the following ways 877 221 1252 info chaney inst com Register your Product Submit Feedback Ideas Support User Forum Installation Videos Replacement Parts I...

Page 3: ...lation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a cir...

Page 4: ... buckets tip and see water drain through the rain gauge 4 A few seconds after each bucket tip the display unit displays rainfall in approximately 0 01 or more increments 5 The cup of water should take more than 10 minutes to empty a quicker period will result in inaccurate calibration Try to simulate a normal steady rainfall When cup is empty of water display unit should register 1 06 Tips There s...

Page 5: ...ssure on right with trend Rising Steady or Falling 4 Historical Barometric Pressure Pressure reading 12 hours ago 5 Weather Select Heat index dew point wind chill indoor temperature humidity and rainfall rate in mm of rain per hour 6 Wireless Sensor Signal Strength 7 Alarm On Off Indicator for Selectable Category 23 8 Programmable Alarm Setting 9 Current Outdoor Temperature Arrow icon indicates di...

Page 6: ...e icon disappeared from the display unit Learning Mode must be completed before the forecast and pressure will be accurate Allow the unit to run continuously for 33 days Battery removal or resetting the display unit restarts Learning Mode After 14 days forecast should be fairly accurate however Learning Mode continues to calibrate for a total of 33 days Problem Possible Solution Inaccurate tempera...

Page 7: ...ooting Display screen not working Check that the batteries are installed correctly Batteries may need to be replaced Reset the display by pressing the reset button located on the back of the display unit Date and time will need to be entered after a reset A B C 7 Display Unit Setup PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AN...

Page 8: ...few minutes afterwards until one of the following happens 1 SNOOZE Press any button Alarm silences but sounds again if the alarm condition reoccurs 2 Turn the alarm OFF Deactivates the alarm reached Alarms include outdoor temperature outdoor humidity wind speed heat index dew point wind chill indoor temperature and indoor humidity The rain alarm does not require a preset numerical value but instea...

Page 9: ... and a pressure chart The chart tracks and displays the change in pressure so you can monitor the rate of change over time Rainfall Event The rainfall feature tracks rain accumulation over all time the current month and current rainfall event Current event clears when no rain registers for 8 hours OR no rain registers for 1 hour and pressure rises by 03inhg or more Programmable Weather Alarms Each...

Page 10: ... rain measurement SOLAR CELL ORIENTATION Install the sensor with the solar cell facing SOUTH This ensures the cell receives as much sun as possible and orients wind direction 11 10 5 in 1 Sensor Installation 1 Fasten mounting base included to a post or pole not included using the 4 longer screws included in the hardware bag 2 Insert the mounting base into the hole on the bottom of the sensor 3 Mak...