background image

Calibration 

Calibrat

e Temper

ature and Humidity 

The indoor / outdoor tem

peratur

e and humidity readings can be calibr

ated on 

the displa

y unit to im

prov

e accuracy

. Calibration can im

prov

e accuracy when 

sensor placement or envir

onmental f

actors im

pact your dat

a accuracy

.

 

1. 

To access calibr

ation mode, press AND HOLD t

he “

”, “Set”, and “

” 

buttons (locat

ed on the bac

k of the displa

y unit) for at least 5 seconds.

 

2. Once in calibr

ation mode, the pr

efer

ence you ar

e currentl

y setting will 

blink on the displa

y.

 

3. Pr

ess the “

” or “

” buttons t

o calibrat

e the dat

a value higher or lo

wer 

from t

he actual reading.

 

4. Pr

ess the “Se

t” button t

o confirm t

he calibration adjustment. The “ 

” icon 

will remain illuminat

ed next t

o calibrat

ed values.

 

5. The ne

xt adjustable dat

a will begin flashing, indicating it is ready t

o be 

calibrat

ed. Repeat S

teps 1 - 4 t

o calibrat

e additional data.

 

After 5 seconds of inactivity

, the displa

y will save t

he adjustments and exit 

calibration mode. N

ote: Calibr

ations will be erased if t

he display is r

eset or if 

batter

ies are r

emoved and t

he pow

er adapter is un

plugged. 

Calibrat

e Barome

tric Pr

essure 

The weat

her station def

ault pressur

e mode is “AUT

O.” In aut

o mode, the 

pressur

e will calibrat

e itself over a 1

4 day Lear

ning Mode. Barome

tric pr

essure 

can be manually calibr

ated:

 

1. 

Press AND HOLD t

he “Set” butt

on (located on t

he back of t

he display unit) 

for at least 1

0 seconds to ent

er manual pressur

e mode.

 

2. The un-calibr

ated pr

essure will be displa

yed. Pr

ess AND HOLD the “

”, 

”, and “Set” butt

ons for at least 5 seconds.

 

3. Pr

ess and release t

he “Set” butt

on until barome

tric pr

essure is flashing. 

4. Pr

ess the “

” or “

” buttons t

o calibrat

e the dat

a value higher or lo

wer 

from t

he actual reading.

 

5. Pr

ess the “Se

t” button t

o confirm t

he calibration adjustment. 

Not

e: The “ 

 ” icon will remain illuminat

ed next t

o the calibr

ated v

alue.

 

After 5 seconds of inactivity

, the displa

y will save y

our adjustments and exit 

calibration mode. N

ote: Calibr

ation will be erased if t

he display is r

eset or if 

batter

ies are r

emoved and t

he pow

er adapter is un

plugged

 

To e

xit manual pressur

e mode and retur

n to aut

o mode press and hold t

he

 

“Set” butt

on for at least 1

0 seconds.

 

12 

Summary of Contents for 02050CCDI

Page 1: ...Display Setup 6 Intelli Time Clock 7 Set the Time Date and Units 7 Backlight Settings 7 Placement Guidelines 8 Using the Weather Station 9 Troubleshooting 10 Care and Maintenance 11 Calibration 12 Replace Intelli Time Battery 13 Specifications 14 FCC Information 14 Customer Support 15 Questions Contact Customer Support at 877 221 1252 or visit www AcuRite com SAVE THIS MANUAL FOR FUTURE REFERENCE ...

Page 2: ...ay unit with tabletop stand 2 Outdoor sensor 3 Instruction manual 4 Power adapter IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE PRODUCT REGISTRATION Register online to receive 1 year warranty protection www AcuRite com Register a Product Features and Benefits 1 2 3 4 5 OUTDOOR SENSOR 1 Integrated Hanger For easy placement 2 Wireless Signal Indicator Flashes when data is being se...

Page 3: ...umidity is trending 7 Current Indoor Humidity 8 Current Indoor Temperature 9 Moon Phase 10 AUTO DIM Icon Indicates display backlight AUTO DIM mode activated 11 Display Low Battery Indicator 12 Removable Tabletop Stand 13 Date 14 Time 15 Current Barometric Pressure Arrow icon indicates the direction pressure is trending 16 Learning Mode Icon Disappears after weather forecast self calibration is com...

Page 4: ...ds 3 SET Button for setup preferences 4 Button for setup preferences and viewing LOW records 7 8 9 10 5 A B C Switch ID code that must match sensor s A B C switch to ensure units synchronize 6 RESET Button Full reset to factory defaults 7 Plug in For Power Adapter 8 Battery Compartment 9 Intelli Time Battery Compartment 10 Battery Compartment Cover 4 ...

Page 5: ...y duty or rechargeable batteries are not recommended The sensor requires lithium batteries in low temperature Install Batteries 2 AA batteries conditions Cold temperatures can cause alkaline batteries to function improperly Use lithium batteries in the sensor for temperatures below 20ºC 4ºF 1 Slide off the battery compartment cover Take note of the A B C switch setting inside the battery compartme...

Page 6: ...which is not to be used for an extended period of time Follow the polarity diagram in the battery compartment Promptly remove dead batteries from the device Dispose of used batteries properly Only batteries of the same or equivalent type as recommended are to be used DO NOT incinerate used batteries DO NOT dispose of batteries in fire as batteries may explode or leak DO NOT mix old and new batteri...

Page 7: ...KST HAST NST AEST ACST AWST CLOCK HOUR CLOCK MINUTE CALENDAR MONTH CALENDAR DATE CALENDAR YEAR TEMPERATURE SCALE ºF or ºC BAROMETRIC PRESSURE SCALE inHg or hPa If you live in an area that observes daylight saving time DST should be set to ON even if it is not currently Daylight Savings Time You will automatically exit SETUP MODE if no buttons are pressed for 20 seconds Enter setup mode at any time...

Page 8: ...ll covered tree branch The best location is 1 to 2 metres 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor Important Placement Guidelines To ensure accurate temperature measurement place units out of direct sunlight and away from any heat sources or vents Display unit and outdoor sensor must be within 100 m 330 ft of each other To maximize wi...

Page 9: ...Subtle variations in barometric pressure greatly affect the weather This weather station displays the current pressure with an arrow icon to indicate the direction the pressure is trending FALLING STEADY or RISING Moon Phase Track the phases of the moon conveyed through simple lunar phase icons NEW WAXING 1ST FULL 3RD WANING CRESCENT QUARTER QUARTER CRESCENT High Low Records Today s high and low r...

Page 10: ...ndoors and remove batteries from each 2 Make sure the A B C switch on both units match 3 Reinstall batteries in the outdoor sensor 4 Reinstall batteries in the display unit 5 Let the units sit within a couple feet of each other for about 20 minutes to gain a strong connection Sometimes changing to a different channel can help Inaccurate forecast Weather Forecast icon predicts conditions for the ne...

Page 11: ...ds to be replaced see page 13 Once the new battery is installed time and date will need to be set manually If your AcuRite product does not operate properly after trying the troubleshooting steps visit www AcuRite com or call 877 221 1252 for assistance Care and Maintenance Display Unit Care Clean with a soft damp cloth Do not use caustic cleaners or abrasives Keep away from dust dirt and moisture...

Page 12: ...ll be erased if the display is reset or if batteries are removed and the power adapter is unplugged Calibrate Barometric Pressure The weather station default pressure mode is AUTO In auto mode the pressure will calibrate itself over a 14 day Learning Mode Barometric pressure can be manually calibrated 1 Press AND HOLD the Set button located on the back of the display unit for at least 10 seconds t...

Page 13: ...ores the time and date settings The battery has a shelf life of several years Time and date will need to be entered after replacing Intelli Time battery To replace the Intelli Time battery 1 Locate the coin cell battery compartment door in the battery compartment of the display unit Unscrew and remove the compartment cover 2 Insert 1 x CR2032 coin cell battery into the battery compartment as shown...

Page 14: ...l installation This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determ...

Page 15: ...laced by Chaney Transportation costs and charges for returned goods shall be paid for by the purchaser Chaney hereby disclaims all responsibility for such transportation costs and charges This warranty will not be breached and Chaney will give no credit for products it manufactures which have received normal wear and tear been damaged including by acts of nature tampered abused improperly installe...

Page 16: ...ed to provide you with information you can depend on to Plan your day with confidence www AcuRite com Chaney Instrument Co All rights reserved AcuRite is a registered trademark of the Chaney Instrument Co Lake Geneva WI 53147 All other trademarks and copy Printed in China rights are the property of their respective owners AcuRite uses patented technology 02050CCDI INST 051115 Visit www AcuRite com...

Reviews: